13
Charger Display
Mode
Charging Indicator
(green)
Error Indicators
(red)
Fuel Gauge on
Battery Pack
Note
Self-inspection
completed
Flash once
Flash once
Off
All the four
indicators flash once
Self-inspection failed
Either or both are off
Off
At least one will
have no reaction
when the charger is
plugged in.
Normal Charging
Flashing
Off
Flashing
according to
the current
capacity level.
The charger will
automatically start
charging the battery
pack, if the battery
pack temperature is
within the charging
temperature range.
Fully Charged
Steady
Off
Off
Hot/Cold Battery
Off
Steady
Off
Remove the battery
from the charger.
Error
Off
Flashing or Off
Off
Charging Error.
NOTICE: Charger may become warm with several continuous charge cycles. This is part of
the normal operation of the charge. Charge in a well-ventilated area.
Charger Error
If the charger self-inspection fails to react when the charger is plugged in, the causes include
no power to the charger, bad contacts, or a charger failure. Check to see if the charger self-
inspection can be activated when the charger is plugged in again or plugged into a different
outlet. If it still fails, have the charger serviced by an Authorized SKIL Service Station.
Battery Pack Error
If the charger detects a problem, the red Error Indicator will begin flashing. Remove and
reinsert the battery pack in the charger. If the Error Indicator still flashes, try charging a
different battery pack.
a. If a different battery pack charges normally, have the first failed battery pack serviced by an
Authorized SKIL Service Station.
b. If a different battery pack also fails to charge, the problem may be with the charger. Have
the charger serviced by an Authorized SKIL Service Station.