10. Troubleshooting
Possible
malfunctions
Cause
Elimination, detection of the malfunction
TLMR does not
work
DIP switch ON/ OFF in OFF position
Put the DIP switch in the ON position. The test of the storage pro-
gram starts (10 s)
There is no connection to the power supply.
Batteries are empty (TLMR 101)
Connect the TLMR to the correct power supply
Replace the batteries
Fault - storage test
Fault - overcurrent (2 hours pause)
Fault - TLMR blocked
Switch the TLMR on again. The test of the storage program must
lapse automatically, i. e. the LEDs flash during 10 s following the
sample “Switch-on process“.
The red LED flashes following the sample “Pause after overcurrent“
The red LED flashes following the sampe “Pause after blockade“
TLMR works, but
does not dispense
lubricant
Air in the supply line
Cartridge is empty
Remove the supply line, put the DIP switch into the “Venting“ positi-
on. Let the TLMR run until lubricant is supplied free of bubbles
Green LEDs flash following the sample “Pre-empty warning“
Replace cartridge and batteries, if need be