19
SKF TKSA 20
3.8.3 Horizontal alignment
Move the measuring units to the 3 o’clock position (fig.
23).
Observe the coupling and feet values live adjustment.
Fig. 23. The 3 o’clock position
Machine misalignment should be within the
manufacturer’s specified tolerances. In case such
tolerances are missing, table 1 can again be used as a
general recommendation.
a) If the measured coupling values are within the
tolerances, no sideways adjustment is necessary.
b) If the measured coupling values are higher than
the acceptable tolerances check the recommended
correction on the feet.
Fig. 24. Horizontal alignment
Summary of Contents for TKSA 20
Page 1: ...Instructions for use SKF Shaft Alignment Tool TKSA 20...
Page 2: ......