Unit Configuration
Network Configuration
SKF Multilog On
-Line System IMx-S
3 - 9
User Manual
Table 3-10: TP/IP address/Unit ID when configured by HEX rotary switches.
TCP/IP
address/Unit ID
HEX1 (x10)
HEX2 (x1)
Software defined
01
02
↓
99
0
0
0
↓
9
0
1
2
↓
9
Factory default configuration TCP/IP address:
10.0.0.1XY
Configurator (RS232) Interface
RS232 interface is used only when the required basic network configuration setup is
being done.
The RS232 connector is located on the right hand side of IMx-S front panel, labeled as
COM.
Use a serial null modem cable with a 9-pin D-
SUB connector.
It is recommended to use a short length cable for RS232 interface in order to maintain
full communication speed.
Important - RS232 connector is used only when the required basic network
configuration setup is being done. Therefore, the cable should not be connected to
RS232 connector at any other time.
Table 3-11: RS232 connector pinout.
RS232 Connector Pinout
Pin
Description
1
N.C.
2
Rx
3
Tx
4
N.C.
5
GND
6
N.C.
7
N.C.
8
N.C.
9
N.C.
N.C. = Not Connected