MTx
SOFTWARE
SKF Condition Monitoring Centre – Steyr
1 - 6 - 41
Acceleration configuration
* Click on ’Device – Input Configuration – Acceleration Input’ or press STRG+I to open the
dialog box.
Fig. 4/25
• Acceleration input:
The configuration of the acceleration sensor is saved to the current MTx device.
The calibrator factor can be used for fine tuning the sensor output by using a exciter
with a defined g value.
Default value: 100, if no fine tuning is performed
For description of the parameters see section 3.2.1.
The sensitivity of 34 mV/g is valid for triax sensor [CMSS-ONL-1500E-2].
Possible calibration values 50 to 150%.
Rotation configuration
* Click on ’Device – Input Configuration – Rotation Input’ or press STRG+R to open the
dialog box.
Fig. 4/26
• Rotation input:
The configuration of the rotation sensor (24 V, 5 V, 1 Vpp) type is saved to the current
MTx device. For description of the parameters see section 3.2.2.
If the sensor value is above the operation time, it will recorded to the matrix value, see
Fig. 4/42.
Summary of Contents for MTx
Page 2: ......
Page 6: ...VERSION OF MANUAL MTx 1 6 4 SKF Condition Monitoring Centre Steyr Room for notes...
Page 40: ...SOFTWARE MTx 1 6 38 SKF Condition Monitoring Centre Steyr Fig 4 19...
Page 45: ...MTx SOFTWARE SKF Condition Monitoring Centre Steyr 1 6 43 Fig 4 29 Examples...
Page 55: ...MTx SOFTWARE SKF Condition Monitoring Centre Steyr 1 6 53 Fig 4 44...
Page 56: ...SOFTWARE MTx 1 6 54 SKF Condition Monitoring Centre Steyr Room for notes...
Page 64: ...APPENDIX MTx 1 6 62 SKF Condition Monitoring Centre Steyr 5 4 DIMENSION DRAWINGS Fig 5 5...
Page 65: ...MTx APPENDIX SKF Condition Monitoring Centre Steyr 1 6 63 Fig 5 6...
Page 67: ......