6. Installation
6.1 General information
Only qualified technical personnel may
install, operate, maintain, and repair the
products described in these Instructions.
Qualified technical personnel are persons
who have been trained, assigned, and in-
structed by the operator of the final product,
into which the described product shall be
integrated.
Such persons are familiar with the relevant
standards, rules, accident prevention regu-
lations, and operating conditions as a result
of their training, experience, and instruction.
They are qualified to carry out the required
activities and in doing so recognize and
avoid any potential hazards.
Before assembling the product, the packag-
ing material as well as possible transport
locking devices must be removed.
Keep the packaging material until any dis-
crepancies are resolved.
NOTE
Technical data (see chapter 4).
6.2 Attachment
Protect the product against humidity (ob-
serve IP protection class) and vibration and
install it in an easily accessible position to
ensure all other installations can be carried
out without any problem. For indications on
the maximum admissible ambient tempera-
ture see the technical data.
○
During assembly and particularly during
any drilling work always pay attention to
the following:
Other units must not be damaged by the
assembly.
○
The product must not be installed within
the range of moving parts.
○
The product must be installed at an ad-
equate distance from sources of heat and
coldness.
○
Adhere to safety distances and legal pre-
scriptions on assembly and prevention of
accidents.
CAUTION
Electric shock
Make sure to disconnect the
pump from the power supply
before carrying out works on
electrical parts.
Connection of the pump must be
provided by a safe galvanic isola-
tion (PELV) always.
Installation position:
○
any
○
Minimum length of tube line between
pump and change-over device: 2 m
6. Installation