![SKF Linkoln DU1 Assembly Instructions Manual Download Page 10](http://html1.mh-extra.com/html/skf/linkoln-du1/linkoln-du1_assembly-instructions-manual_1287010010.webp)
10
EN
EN
○
All relevant persons (e.g. operating per-
sonnel, supervisors) must be informed
of the activity prior to starting any work.
Precautionary operational measures and
work instructions must be observed.
○
Ensure through suitable measures that
movable or detached parts are immobi-
lized during the work and that no limbs
can be caught in between by inadvertent
movements.
○
Assemble the product only outside of the
operating range of moving parts, at an
adequate distance from sources of heat
or cold.
○
Prior to performing work, the product
and the machine or system in which the
product is or will be integrated must be
depressurized and secured against un-
authorized activation.
○
Carry out all works on electrical compo-
nents using voltage insulated tools only.
○
Ensure proper grounding of the product.
○
Undertake drilling at non-critical, non-
load bearing parts only.
○
Other units of the superior machine
must not be damaged or impaired in
their function by the installation of the
product.
○
No parts of the centralized lubrication
system may be subjected to torsion,
shear, or bending.
○
Use adequate lifting devices when work-
ing with heavy components.
○
Repairs may be performed with original
SKF spare parts only.
○
Any malfunctions which may affect safety
and functionality must be remedied
immediately.
○
Avoid mixing up or wrong assembly of
disassembled parts. Mark these parts
accordingly.
○
Modifications or changes to the change-
over device are allowed only upon prior
consultation with the manufacturer.
1.7
Assembly, maintenance, malfunctions, modification, shutdown, disposal
1.8 Intended use
Supply of lubricants within a dual-line sys-
tem following the specifications regarding
the pressure and flow range made in these
Instructions:
The limit values specified in the technical
data, particularly the maximum operat-
ing pressure of 350 bar, must never be
exceeded.
Any other or exceeding use is considered to
be improper use.
For ranges going beyond the specified ones,
the electromotive change-over device type
EM-U3 can be used in combination with
end-of-line pressure switches.