2. Installation
General
The SKF Multipoint automatic lubricators LAGD 1000 are designed to lubricate plant and
machines. They must not be used for vehicle lubrication. They are capable of delivering
greases up to NLGI grade 2. The pump units differ in the way they can be electrically
connected as well as in number of lubrication points they can supply.
2.1 Preparation of lubrication points
Initially, check all lubricating points for possible damage and test the permeability by
means of a grease gun or a different lubrication device.
When operating new machines, ill any existing cavities in bearing points with a respective
lubricant. Otherwise, bearing damage may occur as a result of insuficient lubrication.
Remove the grease nipples at the lubricating points.
Screw in the supplied connectors (G
1
/
8
) to the lubricating points.
Ensure cleanness. Even minor contamination may result in system errors
or bearing damage.
Fig 4 Check the permeability of the lubricating points and ill any cavities in the bearing points.