Introduction
Scanning Module
1 - 10
Inspector 400 Ultrasonic Probe
User Manual
plugged in to the front end of the metered pistol
housing by aligning the plug with the receptacle and
inserting it firmly.
Figure 3. The Scanning Module.
To use the Scanning Module:
•
Plug in to front end.
•
Start with the sensitivity selection dial at
maximum (8).
•
Start to scan the test area.
•
Measure from the “gross to the fine.” If there is
too much ultrasound in the area, reduce the
sensitivity, place the Rubber Focusing Probe
(described below) over the scanning module and
proceed to follow the sound to the loudest point.
If it is difficult to locate the sound due to a high
intensity signal, keep reducing the sensitivity
and follow the meter to the loudest point.
Rubber Focusing Probe
- The Rubber Focusing
Probe is a circular shaped rubber shield used to block
out stray ultrasound, and to assist in narrowing the
field of reception of the Scanning Module. It also