SKF 234-11454-1 Service Manual Download Page 7

3

2

1

- 7 -

951-150-032-EN

Version 09

EN

3. Overview, functional description

3.1  Progressive metering device overview with universal piston detector 234-13163-9 or bipolar piston detector 234-11454-1 

Mounting dimensions for universal and bipolar piston detectors, Fig. 1

VPBM

VPK

VP

SSV

PSG1

PSG2

PSG3

SSVD

/SSVL

/SSVDL

SW 12
44-0159-2507

           

SW 24

44-0159-2510

SW 13
419-74455-1

53,6 

(53,3)

53,5 

(53,5)

53,5 

(53,5)

53,8 

(53,5)

53,8 

(53,5)

40 

(39,5)

54,3 

(54)

54,3 

(54)

SW 12
44-0159-2508

SW 12
44-0159-2508

SW 12
44-0159-2509

SW 12
44-0159-2509

SW 13
419-74455-1

(....) 

= mounting dimension of previous piston detector

3.  Overview, functional description

Summary of Contents for 234-11454-1

Page 1: ...onally with cable break protection L 1 2 4 L L 2 4 1 L 3 L L 1 4 4 1 Bipolar piston detector 234 11454 1 Note Only for use in connection with SKF lubrication pumps of the series KFAS KFBS or KFGS pump...

Page 2: ...ston detector Model Magnetic sensor M G Item number 234 13163 9 and 234 11454 1 with all relevant harmonization legislation of the European Union at the time of placing on the market Furthermore the f...

Page 3: ...e product Intentional or gross negligence Use of non original SKF spare parts The maximum liability for loss or damage resulting from the use of our products is limited to the purchase price Liability...

Page 4: ...ive gear gloves Bullet list items Wear personal protective gear protective clothing Indicates the requirements that must be met for the actions described in the following Pressure injection General no...

Page 5: ...tector 234 11454 1 7 3 2 Design 8 3 2 1 Functioning 8 3 3 Information on metering device series VP VPB VPK PSG1 PSG2 PSG3 9 4 Technical data 10 4 1 General technical data 10 4 2 Connection options 234...

Page 6: ...he operator must also ensure that the staff fully understands the content of the instructions Putting the products into operation or operating them without having read the instructions is prohibited 2...

Page 7: ...nsions for universal and bipolar piston detectors Fig 1 VPBM VPK VP SSV PSG1 PSG2 PSG3 SSVD SSVL SSVDL SW 12 44 0159 2507 SW 24 44 0159 2510 SW 13 419 74455 1 53 6 53 3 53 5 53 5 53 5 53 5 53 8 53 5 5...

Page 8: ...lar piston detector is available only in a two wire design The signal voltage can be applied to either pin 1 or pin 4 3 2 1 Functioning When the piston detector is actuated piston stroke a yellow LED...

Page 9: ...Kabelbaum Pumpe Pin 5 Aderfarbe gelb Kabelbaum Kolbendetektor Pin 1 Aderfarbe braun Kabelbaum Pumpe Pin 6 Aderfarbe schwarz Kabelbaum Kolbendetektor Pin 4 Aderfarbe schwarz SKF Lubrication Systems Ge...

Page 10: ...Nm 7 0 5 Circuit state display LED Yellow lights up on damping Electrical connection M12x1 plug in connection gold plated contact Sensing range Bipolar piston detector sensing distance mm 2 2 conditi...

Page 11: ...reversal protection Yes Reversible Output function NO contact Voltage drop V 3 5 4 5 Minimum load current mA 5 Residual current mA 0 8 Current carrying capacity mA 100 Short circuit proof Yes Overload...

Page 12: ...olar piston detector also has a thick black marking ring around its circumference Visual differentiations of the adapters for Marking Item number Progressive metering devices of the series VP and PSG2...

Page 13: ...2 Connection options 234 13163 9 12 24V DC 3 wire PNP Adernfarben Core colors br brown braun ws white wei sw schwarz black bl blau blue 1 2 3 4 1 2 3 4 12 24 V DC br ws sw bl 0 V DC ground Load 1 2 3...

Page 14: ...n Core colors br brown braun ws white wei sw schwarz black bl blau blue 1 2 3 4 1 2 3 4 12 24 V DC br ws sw bl 0 V DC ground load 1 2 3 4 1 2 3 4 12 24 V DC br ws sw bl 0 V DC ground load 1 2 3 4 1 2...

Page 15: ...farben Core colors br brown braun ws white wei sw schwarz black bl blau blue 1 2 3 4 1 2 3 4 12 24 V DC br ws sw bl 0 V DC ground load 1 2 3 4 1 2 3 4 12 24 V DC br ws sw bl 0 V DC ground load 1 2 3 4...

Page 16: ...piston detector VPB VPK PSG1 VP PSG2 PSG3 Installation of the new piston detector SSV SSVL SSVD SSVDL SSVC SLC VSG VSL 5 Installation 4 3 2 1 4 3 2 1 VPB VPK PSG1 VP PSG2 PSG3 SSV SSV L SSVD SSVDL SSV...

Page 17: ...and metering device If possible place a drip pan for the dis charging lubricant below the correspond ing metering device Place individual parts of the new piston detector replacement kit 1 on a clean...

Page 18: ...e 2 On the subsequent metering device strokes the signal from the piston detector must be received by the customer s moni toring equipment Carry out a few strokes of the metering device and check the...

Page 19: ...rrectly Check engagement depth of adapter and piston detector tighten if necessary Piston detector overtightened Disconnect the piston detector check the signal replace the piston detector if damaged...

Page 20: ...Check for any excessive magnetic fields in the assembly area of the metering device Proceed as follows Remove the metering device with piston detector from the in stallation location and carry out a f...

Page 21: ...tector Piston detector 234 13163 9 connected incorrectly Connect the piston detector in accordance with chapter 4 2 Connection options 234 13163 9 3 wire PNP Short circuit If pin 2 is connected to pin...

Page 22: ...a second sensor or an actuator is connected using a Y splitter cable w r o n g c o n n e c t i o n Pin 4 Pin 2 12 24 V DC 1 2 3 4 br ws sw bl 1 2 3 4 br ws sw bl 1 2 3 4 1 4 3 1 2 3 4 br ws sw bl 1 2...

Page 23: ...44 0159 2509 VP O ring WVN 501 12x1 5 VPK adapter sleeve 44 0159 2508 VPK O ring WVN 501 10x1 5 VPB adapter sleeve 44 0159 2507 VPB O ring WVN501 10x1 PSG1 adapter sleeve 44 0159 2508 PSG1 O ring 96...

Page 24: ...Nov 9 2021 Version 09 SKF Lubrication Systems Germany GmbH Walldorf Plant Heinrich Hertz Str 2 8 DE 69190 Walldorf Tel 49 0 6227 33 0 Fax 49 0 6227 33 259 E mail Lubrication germany skf com www skf c...

Reviews: