6

SAMPLE PUMP OPERATION

The user may choose to: 
•  Operate the pump manually in the 

fi

 eld (on/o

 )

•  Program a schedule into the pump manually
•  Program the pump for multiple schedules from a PC 

with optional DataTrac

®

 for Leland Legacy Software (

see 

Ordering Information, Accessories

).

See the Leland Legacy Quick Guide to operate the SKC 
Leland Legacy Sample Pump. 

For advanced programming, see 

the complete Leland Legacy Pump Operating Instructions.

Charging the Battery

Completely charge a new ba

tt

 ery pack using the SKC-approved charger (Cat. No. 

223-241) before operating the pump. It may be necessary to charge the ba

tt

 ery a 

few times before maximum ba

tt

 ery capacity is achieved.

Cautions: 

•  Do not charge or operate pump with or without charger in hazardous 

locations.

•  Use only the SKC-approved charger for this pump. Use of an 

unapproved charger may damage the ba

tt

 ery and pump and VOIDS 

ANY WARRANTY.

•  Do not open, disassemble, short circuit, crush, incinerate, or expose the 

ba

tt

 ery to 

fi

 re or temperatures in excess of 212 F (100 C).

•  Tampering with the ba

tt

 ery pack VOIDS ANY WARRANTY.

•  Ensure proper orientation of charging cable before plugging it into the 

charging jack. Improper orientation/contact will short-circuit the ba

tt

 ery 

and VOIDS ANY WARRANTY.

•  Short-circuiting the ba

tt

 ery pack will render it immediately inoperative.

•  Failure to follow warnings and cautions VOIDS ANY WARRANTY.

The ba

tt

 ery pack may be kept on the SKC-approved charger for an 

inde

fi

 nite time.

1.  Insert the plug from the charging unit into the 

charging port on the ba

tt

 ery adapter (on top of the 

external ba

tt

 ery assembly).

2.  Insert plug from power supply into the jack on the 

charging unit.

3.  Install the appropriate wall plug on the power 

supply and plug power supply into a wall outlet.

The ba

tt

 ery will recharge in approximately 15 

hours. For a complete charge, do not run the pump 
connected to the external ba

tt

 ery assembly during 

charging. After charging is complete, disconnect 
ba

tt

 ery from charger and connect pump to ba

tt

 ery. 

See Ba

tt

 ery Setup

.

1

External 

battery 

assembly

Battery 

adapter

Charging 

unit plug

Power 

supply

Charging 

unit

External 

battery 

assembly

Summary of Contents for DCS

Page 1: ...Operating Instructions SKC Deployable Cartridge Sampler DCS System SKC Inc 863 Valley View Road Eighty Four PA 15330 Form 38048 Rev 1812 ...

Page 2: ...ow rate to 10 L min and record the pre sample flow rate 7 Disconnect calibrator and remove calibration adapter from sampling head 8 Mount bracket at desired location 9 Install sampling head on mounting bracket 10 Install rain cover on sampling head Sampling 1 Turn on pump and record pertinent data Leland Legacy pump may be started manually or automatically see Leland Legacy Quick Guide 2 After des...

Page 3: ... Pump Operation 6 Charging the Battery 6 Reading the Charging Status LED 7 Battery Setup 7 Battery Replacement 7 Leland Legacy Quick Guide 8 Calibration and Sampling 9 Calibration 9 Sampling 10 Sample Removal and Shipping 11 Removing the Media Cartridge from the Sampling Head 11 Storing and Transporting Samples 11 Ordering Information 12 Li Ion Battery Shipment 13 Warranty 13 Indicates a reminder ...

Page 4: ...is packaged in a portable heavy duty Pelican case from which the system operates The SKC DCS System includes a Leland Legacy Sample Pump with connection case and cable two external battery assemblies with adapters packaged separately charger 100 240 V sampling head calibration adapter rain cover for sampling head sample tubing with quick connect fitting calibration tubing and mounting bracket in a...

Page 5: ...omatography high resolution mass spectrometry HRGC HRMS dependent on method used Tubing 3 8 in ID reinforced flexible PVC supplied Temperature Charging 32 to 113 F 0 to 45 C Operating 32 to 104 F 0 to 40 C Storing 4 to 95 F 20 to 35 C Altitude Do not use pump beyond 7500 ft RFI EMI Shielding CE marked Case Dimensions 18 5 x 14 1 x 6 9 in 47 x 36 x 18 cm Complete System Weight 12 20 lbs 5 5 kg Samp...

Page 6: ...See Figure 2 The aluminum foil wrapped cartridge is supplied in an aluminum can with lid so that the sample is protected from light and contamination during transport The filter and sorbent media are combined for extraction followed by GC MS or HRGC HRMS depending on the method used Inlet section PTFE O ring BUNA N O ring Exhaust section The two main components of the DCS System DCS Sampling Head ...

Page 7: ...ridge For deployed applications where method specified solvents are unavailable use isopropyl rubbing alcohol or a clean tissue wipe Do not place any mechanical object in the inlet nozzles O ring Care for the Sampling Head Visually inspect the condition of the BUNA N exhaust O ring See Figure 2 Ensure the O ring surface is smooth i e without cracks cuts or other damage Ensure the O ring is fitted ...

Page 8: ... holder section onto exhaust section 3 Remove media cartridge from aluminum foil and insert into cartridge holder section Ensure airflow arrow on media cartridge points to exhaust section The filter should be on the inlet side of the media cartridge 4 Thread inlet section onto cartridge holder section until just tight Further hand tighten by 1 4 turn only Thread cartridge holder section onto exhau...

Page 9: ...attery to fire or temperatures in excess of 212 F 100 C Tampering with the battery pack VOIDS ANY WARRANTY Ensure proper orientation of charging cable before plugging it into the charging jack Improper orientation contact will short circuit the battery and VOIDS ANY WARRANTY Short circuiting the battery pack will render it immediately inoperative Failure to follow warnings and cautions VOIDS ANY W...

Page 10: ...nsert the plug on connecting cable from pump into the jack on the battery adapter on top of the external battery assembly 2 Insert external battery assembly into a foam compartment in the case Ensure there is no tension on the connecting cable Battery Replacement 1 Record all necessary data before unplugging pump from battery 2 Remove plug on connecting cable from jack on battery adapter on top of...

Page 11: ... new setting and place pump in Hold For CalChek Calibration see operating instructions To change temperature scale from F to C or C to F Press then Press until temperature displays Press or to switch units press until End displays then press to save new setting To change atmospheric pressure scale mm mb In Press then Press until pressure displays then press or to switch units press until End displ...

Page 12: ...p flow rate to 10 L min see Leland Legacy Quick Guide Record the pre sample flow rate See pump and calibrator operating instructions 1 When calibration is completed disconnect calibrator and tubing from calibration adapter Remove calibration adapter from sampling head Use provided short length of calibration tubing to connect inlet of calibration adapter to outlet of a calibrator to form a calibra...

Page 13: ...ay be started manu ally or automatically Record all necessary data before disconnecting pump from battery and reconnecting to new battery 4 After desired sample time has elapsed record sample stop time Remove rain cover from sampling head and reinstate calibration adapter tubing and calibrator see Calibration Record post sample flow rate 5 Turn off pump Record total volume ambient temperature ambie...

Page 14: ...from cartridge holder section 3 Wrap media cartridge in supplied foil or clean aluminum foil and place in supplied aluminum can to protect sample from light and contamination Storing and Transporting Samples 1 Store samples with ice packs 39 2 F 4 C in the field 2 Package and transport samples and blanks with ice packs 39 2 F 4 C until receipt at the analytical laboratory Lift media cartridge from...

Page 15: ...d a 47 mm quartz filter 226 206 Filter PUF XAD 2 PUF contains a 47 mm quartz filter and 2 grams of XAD 2 sorbent sandwiched between two 20 6 mm lengths of PUF 226 207 Accessories TSI 4146 Calibrator Kit 0 01 to 20 L min includes calibrator soft sided case mounting lugs tubing 1 4 in ID battery pack 6 AA batteries inlet filter dampening module NIST certificate and manual 740 4146 DataTrac for Lelan...

Page 16: ... 100 watt hours Wh Consult with your carrier for information on Lithium Battery Shipping Regulations UN 3480 and UN 3481 or visit SKC s website for more information at www skcinc com catalog pdf instructions 1921 pdf SKC LIMITED WARRANTY AND RETURN POLICY SKC products are subject to the SKC Limited Warranty and Return Policy which provides SKC s sole liability and the buyer s exclusive remedy To v...

Reviews: