Troubleshooting
Possible Fault
Corrective Action
Battery pack will not charge
•
Check the battery charger by trying it with a different battery pack.
Replace the battery charger if required.
•
Check the battery pack by connecting it to a known good battery
charger. If the battery pack still will not charge replace the battery pack.
Pump will not operate
•
Check for faulty battery pack by trying a known good battery pack.
Replace the battery pack if required.
Pump flow faults continuously
(224-PCMTX4 & 224-PCMTX8
models only)
•
Filter media back pressure too high. Try a lower flow rate and/or a less
restrictive filter media if the sampling method being used allows this.
•
More than one filter accidentally fitted into sampling head. Ensure that
only one filter is fitted into the sampling head.
•
Filter backing paper fitted in addition to / in place of filter media. Ensure
that only the filter is fitted into the sampling head.
•
Pump particulate filter is blocked (appears black). Replace the
particulate filter.
•
Tubing blocked or crimped. Replace tubing.
Pump cannot acheive required
flow rate
•
Battery pack voltage low. Fully charge the battery pack.
•
Filter media back pressure too high. Try a lower flow rate and/or a less
restrictive filter media if the sampling method being used allows this.
•
Pump is in the low flow mode. Disable low flow mode.
•
Pump valves leaking. Replace valve plate assemblies.
Summary of Contents for 224-44MTX
Page 5: ...www skcltd com 224 UMTXM Issue K Page 3 Blank Page ...
Page 32: ...Page 30 224 UMTXM Issue K www skcltd com Intrinsic Safety Certification ...
Page 34: ...Page 32 224 UMTXM Issue K www skcltd com Intrinsic Safety Certification ...
Page 36: ...Page 34 224 UMTXM Issue K www skcltd com Intrinsic Safety Certification ...