St. Moritz 600 x 500cm
1
610952
610969
610976
© SKAN HOLZ Europe GmbH D-21227 Bendestorf. Technical modifications reserved. All dimensions are approximate dimensions. 04/2018
Foundation according
(to the structural calculations, not included in the scope of delivery):
concrete C25/30,
strip foun-
dation:
w/h = 30/90cm, each 2 Ø 12 top and bottom, bow Ø 6, e < 20cm.
Bottom panel:
t=14cm,Q188A, top and bottom
throughout. Anchoring of the floor beams on the strip foundation using bolts M12, e < 60cm (by customer).
Before the side planks are screwed together, it is imperative that the following is observed:
The position of the wall in
which the bolting is done must
definitely be correct
/ the planks to be joined must be firmly pressed together before final
bolting.
The thread rods to secure the house against storm are secured at the top with a washer and a nut, from below with a wa-
sher, spring and nut to tighten the upper nut of the thread rod without any problem, the spring at the bottom should be
pressed upwards with the thread rod.
The spring may only be tightened slightly
so that the house can work at the top. The
projecting ends of the thread rods have to be cut off at the top
. Even after the house has been completed, attention must
always be paid to the fact that the thread rods are not seated on the floor as otherwise when it is dry, gaps can arise and the
roof is pressed upwards. The thread rods can also be pushed subsequently into the bores. You have to make sure that
each
plank has a bore
and that these are free and
not blocked by shavings or similar
.
In case of varying weather conditions, the wood alters in height (due to 'working'). To avoid the formation of joints, the planks
of the house may not, for example, be joined
to one another through several block planks
as then the wood can no longer
expand.
The
door and the window frames or their respective edging boards
must not be
fastened to the wall planks
. If the door
cannot be closed properly
, this can be adjusted by
turning the hinges
.
According to the static calculations a solid connection between the posts (for projecting roof) and ground is absolutely ne-
cessary. Screw-in supports as well as post anchors for casting into concrete are statically permissible. Drive-in sleeves are
not approved. Assembly with screw-in supports is described in the set-up instructions.
This is only a recommendation.
See
manufacturer's instructions regarding mounting hardware for posts and foundations (bolts). Every construction site and each
construction element exhibits different settling characteristics. Please note that we cannot take this into consideration in our
planning and therefore cannot assume any liability for this factor. Die columns are supplied longer and must be shortened to
the desired length by the customer.
The sealing in the eaves area (block planks/roof boarding) must be provided
by the customer
. Suggestion without obliga-
tion: Use a permanently plastic jointing compound and a 1/4 strip for as sealing.
-
-
-
-
-
-
-
1
2
3
4
5
To the drawings:
6
7
Important information for your wood panel cabin
We are pleased that you have chosen a product of SKAN HOLZ.
Please check the construction set for completeness using the position list in good time before starting construction or
commissioning your construction team.
If individual parts are defective or missing, we will deliver these as quickly as possible.
However, we cannot refund the costs for any resulting construction delays to a construction company.
Please understand that we cannot assume any guarantee fort he following defects:
- incorrect storage before assembly
- incorrect anchoring with the ground or inadequate foundation (foundation according to statics)
- damage due to erection errors, e. g. the house is not level or not right-angled
- damage through a higher level of snow burden than statically envisaged. Recommendation: lad relief of the roof by remo-
ving the snow layer
- storm damage (insurance cases) or violent destruction
- damage through any alteration to the design by the client
- natural formation of cracks, branch holes, twisting, decolouration or similar modification (natural process; has no influence
on the statics)
Storage tips before assembly:
- store pallet on a level and dry surface.
- protect against sunshine and dampness; wood can warp drastically in a loose condition!
Maintenance tips:
The wood is untreated. Accordingly, regular, protective coating is absolutely necessary!
Please observe the attached information sheet “Care instructions/Colour treatment”.
General tips and refers to:
General:
-
Windows and outside doors are supplied with insulating glass. Any additional insulation must be installed
by the customer
.
- The floor can be insulated
by the customer
. Please obtain relevant information from a specialist.
- Recommendation:
predrill all screw holes!
- Regarding basic construction set:
Given that the roof is constantly exposed to the weather, a covering with only one
layer of roofing paper will not be enough over the long-term. An additional covering
with bitumen shingles, alternatively with a material of at least equivalent quality,
must follow.
- for tile roofing:
a standard dimension for tile roofing was determined for calculating the roof lathing.
- Any optional roof insulation (in case of shingling and tile roofing) must be provided
by the customer
; please obtain relevant
information from a specialist.
Shingles and tiles are not included in delivery.
-
We recommend clearing the roof during heavy snowfall!
Summary of Contents for St. Moritz 610952
Page 22: ......