22
2
The POWER (EMERGENCY STOP) and STEAM switches are
on. The POWER light is on and the alarm beeps once.
This is normal operating condition.
3
The POWER (EMERGENCY STOP) and STEAM switches are
on. The POWER & WATER PUMP RUN light are on, and the
alarm beeps once.
This is normal operating condition. The WATER PUMP RUN
light will go off momentarily. (See page 8 “Initial Operation”)
4
Float switch is not detecting water in the water tank due to:
1) Water shortage; OR
2) Malfunction of the float switch in the tank.
1) Add water to the water tank.
2) Disconnect the wire from the float switch. If the signal
clears, replace the float switch.
5
Water probe sensors (High, Com, Low) cannot detect water in the
steam vessel because:
1) Not enough water is present in the vessel; OR
2) Water probe sensors (High, Com, Low) are malfunctioning due
to scale build up.
1)
Wait until the pump refills the vessel. Once the alarm is
deactivated, normal operation can resume.
2)
Clean the water probe sensors. (Refer to Guide No.6 figure)