Instl. Instr. PN 1024034E
©SJE-Rhombus 03/18 ENG
ELECTRICAL SHOCK HAZARD
Disconnect power before installing or servicing this product. A
qualified service person must install and service this product
according to applicable electrical and plumbing codes. Switch
should not be used as main isolating switch for power supply.
EXPLOSION OR FIRE HAZARD
Do not use this product with flammable liquids.
Do not install in hazardous locations as defined by National
Codes or other governing body.
Failure to follow these precautions could result in serious injury or death. Replace product immediately if switch cable becomes damaged
or severed. Keep these instructions with warranty after installation. This product must be installed in accordance with local and national electric
codes, so as to prevent moisture from entering or accumulating within boxes, conduit bodies, fittings, float housing, or cable.
For detailed specifications on this product, or for the complete line of SJE-Rhombus
®
panel, alarm, and switch products, visit our web site at www.sjerhombus.cn
MOUNTING THE SWITCH
WARNING:
Switch has not been evaluated for
use in potable water.
WARNING:
Do not install switch in direct line of
incoming liquid.
Pipe Clamp Installation (Figure A):
1. Place the cord into the clamp as shown
in Figure A.
2. Locate clamp at desired activation level
and secure the clamp to the discharge
pipe as shown in Figure A.
Note:
Do not
install cord under hose clamp.
3. Tighten the hose clamp using screwdriver.
Over tightening may result in damage to
the plastic clamp. Make sure the float
cable is not allowed to touch the excess
hose clamp band during operation.
4. Wire switch as shown in Figure C.
5. Check installation. Allow system to cycle
to insure proper operation. Be sure float
has free range of motion and does not
touch anything.
Note:
All hose clamp components are made of 18-8
stainless steel material. See your SJE-Rhombus
®
supplier for replacements.
Cable Weight Installation (Figure B):
1. Place the cord through cable weight as
shown in Figure B.
2. Locate cable weight at desired activation
level. Lock position of cable weight by
turning lid counter clockwise. Note: If
position adjustment is needed, push down
on lid and turn clockwise to loosen.
3. Wire switch as shown in Figure C.
4. Check installation. Allow system to cycle
to insure proper operation. Be sure float
has free range of motion and does not
touch anything.
Figure C
125/250 VAC
NORMALLY OPEN/PUMP DOWN
125/250 VAC
NORMALLY CLOSED/PUMP UP
On SPDT models, insulate unused brown or black wires with wire nut. Wire can become electrically hot.
In 250 VAC installations, one side of the line going to the load is always
HOT
. This condition exists if the switch is on or off. Install double pole disconnect on all 230 VAC circuits.
SJE QUEST
™
SPDT ONLY
SJE QUEST
™
w/ground plate
SJE QUEST
™
NORMALLY OPEN/NORMALLY CLOSED
125/250 VAC
Figure A
Figure B
tether
length
pumping
range
Determining Pumping Range in Centimeters
10 14 18 22 26 30
25 30 36 41 45 51
Use values published as a guide. Pumping ranges are based on
testing in non-turbulent conditions. Range may vary due to water
temperature, cord type and cord shape. Note: As the tether length
increases, so does the variance of the pumping range.
tether
length
pumping
range
Determining Pumping Range in Centimeters
9 15 23 30 38 46
23 30 45 60 75 91
Due to weight of cable, pumping range above horizontal is NOT
equal to pumping range below horizontal. Use values published
as a guide. Pumping ranges are based on testing in non-turbulent
conditions. Range may vary due to water temperature, cord type
and cord shape. Note: As the tether length increases, so does the
variance of the pumping range.
TM