TO OPERATE

1. Plug into 240V AC wall socket.
2. To turn on – switch the wall socket on.
3. Turn off – switch the wall socket off.
4. Unplug lead from wall socket when not in use.

Note: The heater EH633 + EH633R (3200W) is a 15AMP 

electric heater. This requires a special 15AMP power 

socket to be installed by a qualified electrician before 

being able to use.

TO OPERATE USING REMOTE CONTROL, 

WHERE FITTED

NOTE: REMOTE CONTROL WILL ONLY OPERATE 
FROM THE STANDBY MODE.

Turn ON

1. Plug into 240V AC wall socket.
2. Switch the wall socket on.

3. Turn the unit switch on - it will glow Red - Standby 

Function On -

4. Using the remote press “ON”, the heater will come on 

and a small blue LED will glow

Turn OFF

1. Using the remote, press “OFF”, the heater will turn off 

and the small LED light will go out.

2. Turn the unit switch off, the red LED will go out.
3. Switch the wall socket off.
4. Unplug the lead from the wall socket when not in use

CLEANING

Always ensure that the wall heater has been left for one 

(1) hour to cool before cleaning.

1. Turn off and disconnect from mains power, allow to 

cool.

2. Wipe unit over with a damp clean soft lint free cloth.
3. For stubborn marks you can use a mild dish washing 

solution on a damp clean soft lint free cloth.

NEVER allow water or a mild dish washing solution to 
enter or drip onto the wall heater.
NEVER use solvents, e.g. Petrol, Toluene, Methylated 
Spirits etc to clean the floor heater, as these will damage 
the surface finish and may cause a fire when unit is next 
used.

Summary of Contents for Gasmate OPTIMUM EH600 Series

Page 1: ...ES Important Retain these instructions for future use 03841 11 18 Metal radiant heater with non glowing element Adjustable wall and ceiling bracket Black anodised aluminium 1 5m long power cord Designed for indoor and outdoor use Ideal for use in alfresco areas verandahs and garages EH633 EH633R requires 15A power point to be installed by qualified electrician ...

Page 2: ...is NOT designed to run off an extension cord If you require an additional power point please have one installed by a qualified electrician The use of extension cords may cause power voltage loss which will result in damage to the appliance this will NOT be covered under warranty Installation Always ensure you select the correct fixing accessories which suit the particular wall ceiling material you...

Page 3: ...le system with this heater DO NOT clean the heater while the heater is on or plugged into the mains power supply DO NOT touch any part of the heater while on hot surfaces may burn DO NOT use the wall heater as a dryer DO NOT attempt to modify the heater power cord power plug or the supplied accessories in any way DO NOT expose the heater to rain water or use in damp wet conditions NEVER cover this...

Page 4: ...allation of a 15AMP socket by a qualified electrician before use TECHNICAL SPECIFICATION MODEL EH613 EH613R B EH623 EH623R B EH633 EH633R B Remote Control No Yes No Yes No Yes Voltage 220 240V AC 50Hz 220 240V AC 50Hz 220 240V AC 50Hz Input Wattage 1800W 2400W 3200W 15AMP Unit Weight 6 8Kg 7 5Kg 7 5Kg 8 2Kg 9 0Kg 9 7Kg IP Rating IPx4 IPx4 IPx4 Heater specifications can be found on the data label B...

Page 5: ...nt of a power point 3 Mark and drill 2 mounting holes for bracket C 4 Using 2 suitable screws not supplied attach the bracket to the wall or ceiling Note If unsure what screws to use please discuss with your local hardware store 5 Using the nuts and bolts join the bracket C to the heater bracket B and tighten fully 6 Heater is now mounted and ready for use Check the safety distance between the hea...

Page 6: ...eved 5 Insert and tighten the locking bolt if possible to stop any unintentional movement of the heater Note If locking bolt can not be fitted ensure the head tilt bolt is very tight Head Tilt Bolt 30 CEILING MOUNT WITH CHAIN Only use this mounting option if your ceiling is too high 1 Attach the bracket C as noted below 2 Cut chain D not supplied to desired length 3 Using nut and bolt attach chain...

Page 7: ...elow a power point 4 If heater is facing another vertical surface example wall the gap must be at least 1 metre 5 Never mount heater within 1 metre of a water source example tap NOTE Never mount heater into the wall or ceiling Only mount to the surface eave ceiling floor 1 8 m wall eave ceiling minimum 1 8m wall 200mm 90 1m minimum 200mm floor wall heater NO eave ceiling heater 1 8m minimum NO ...

Page 8: ...e unit switch on it will glow Red Standby Function On 4 Using the remote press ON the heater will come on and a small blue LED will glow Turn OFF 1 Using the remote press OFF the heater will turn off and the small LED light will go out 2 Turn the unit switch off the red LED will go out 3 Switch the wall socket off 4 Unplug the lead from the wall socket when not in use CLEANING Always ensure that t...