Parameter
Size:
1
Byte
Available
Settings
:
0,
1.
Default
Setting:
1.
6.
Configure
report
by
Current
Changed
This
parameter
defines
by
how
much
current
changed
must
change
to
be
reported
to
the
Z
‐
Wave
Controller
or
Z
‐
Wave
Gateway,
in
percent.
If
the
rate
of
current
change
ratio
is
greater
than
this
parameter,
the
plug
will
report
the
results,
voltage,
current,
power
and
energy,
that
plug
measure
to
Z
‐
Wave
Controller
or
Z
‐
Wave
Gateway.
‘0’
–
The
Meter
measuring
values
are
not
be
reported
to
controller
and
ignores
the
load
current
changed.
Function:
Meter
Reporting
Setting
Parameter
Number:
6.
Parameter
Size:
1
Byte
Available
Settings
:
0
–
100
(%).
Default
Setting:
5(%).
7.
Remember
Relay
ON/OFF
status
This
parameter
defines
the
relay
status
if
remember
or
not.
If
remembered,
the
plug
will
restore
the
relay
status
last
power
off
when
the
plug
supply
power
next
time.
Function:
Remember
Relay
Status
Parameter
Number:
7.
Parameter
Size:
1
Byte
Available
Settings
:
0
,
1
0
–
Don’t
Remember,
the
relay
will
keep
OFF
when
Plug
Supply
Power.
1
–
Remember
the
Relay
Status.
Default
Setting:
1.
8.
Configure
Plug
Time
switch
Function
This
parameter
defines
the
timer
function
Enable/Disable.
This
parameter
can
be
configured
with
0
or
1,
where
0
means
disable
time
switch
function
and
1
enable.
The
period
will
be
defined
in
parameter
#9.
If
this
parameter
is
Set
to
1,
and
when
turn
the
plug
relay
on,
the
timer
in
plug
start
run
with
time
period
defined
in
parameter
#9
and
the
plug
will
turn
the
relay
off.
Function:
Time
switch
Configure
Parameter
Number:
8.
Parameter
Size:
1
Byte
Available
Settings
:
0,
1
0
–
Time
switch
Disable.
1
–
Time
switch
Enable.
Default
Setting:
0
9.
Configure
Time
switch
Period
This
parameter
defines
the
period
that
plug
time
switch
off.
This
parameter
can
be
configured
1
~
65535(in
minutes).
If
Parameter
#9
is
set
to
‘1’,
and
relay
is
turn
‐
on,
the
relay
will
be
turn
‐
off
after
delay
this
parameter.
Function:
Time
switch
Configure
Parameter
Number:
9.
Parameter
Size:
2
Byte
Available
Settings
:
1
~
65535(minutes).
Default
Setting:
150(min)
10.
Button
On/Off
Enable
This
parameter
defines
the
button
on/off
function
is
enabled
or
not
on
the
top
of
the
wall
plug.
This
parameter
can
be
configured
0
and
1.
If
this
parameter
is
set
to
‘1’,
users
can
turn
on
and
off
the
wall
plug
by
pressing
the
button
on
the
top
of
the
wall
plug.
If
this
parameter
is
set
to
‘0’,
the
wall
plug
cannot
be
turned
on
and
off
by
pressing
the
button.
Function:
Enable
Button
On/Off