Parameter

 

Size:

 

​​

1

 

Byte 

Available

 

Settings

​:​

 

0,

 

1. 

Default

 

Setting:

 

​​

1. 

6.

 

Configure

 

report

 

by

 

Current

 

Changed 

This

 

parameter

 

defines

 

by

 

how

 

much

 

current

 

changed

 

must

 

change

 

to

 

be

 

reported

 

to 

the

 

Z

Wave

 

Controller

 

or

 

Z

Wave

 

Gateway,

 

in

 

percent.

 

If

 

the

 

rate

 

of

 

current

 

change

 

ratio 

is

 

greater

 

than

 

this

 

parameter,

 

the

 

plug

 

will

 

report

 

the

 

results,

 

voltage,

 

current,

 

power 

and

 

energy,

 

that

 

plug

 

measure

 

to

 

Z

Wave

 

Controller

 

or

 

Z

Wave

 

Gateway. 

‘0’

 

 

The

 

Meter

 

measuring

 

values

 

are

 

not

 

be

 

reported

 

to

 

controller

 

and

 

ignores

 

the

 

load 

current

 

changed. 

Function:

 

​​

Meter

 

Reporting

 

Setting 

Parameter

 

Number:

 

​​

6. 

Parameter

 

Size:

 

​​

1

 

Byte 

Available

 

Settings

​:​

 

0

 

 

100

 

(%). 

Default

 

Setting:

 

​​

5(%). 

7.

 

Remember

 

Relay

 

ON/OFF

 

status 

This

 

parameter

 

defines

 

the

 

relay

 

status

 

if

 

remember

 

or

 

not.

 

If

 

remembered,

 

the

 

plug

 

will 

restore

 

the

 

relay

 

status

 

last

 

power

 

off

 

when

 

the

 

plug

 

supply

 

power

 

next

 

time. 

Function:

 

​​

Remember

 

Relay

 

Status 

Parameter

 

Number:

 

​​

7. 

Parameter

 

Size:

 

​​

1

 

Byte 

Available

 

Settings

​:​

 

0

 

,

 

0

 

 

Don’t

 

Remember,

 

the

 

relay

 

will

 

keep

 

OFF

 

when

 

Plug

 

Supply

 

Power. 

1

 

 

Remember

 

the

 

Relay

 

Status. 

Default

 

Setting:

 

​​

1. 

8.

 

Configure

 

Plug

 

Time

 

switch

 

Function 

This

 

parameter

 

defines

 

the

 

timer

 

function

 

Enable/Disable.

 

This

 

parameter

 

can

 

be 

configured

 

with

 

0

 

or

 

1,

 

where

 

0

 

means

 

disable

 

time

 

switch

 

function

 

and

 

1

 

enable.

 

The 

period

 

will

 

be

 

defined

 

in

 

parameter

 

#9. 

If

 

this

 

parameter

 

is

 

Set

 

to

 

1,

 

and

 

when

 

turn

 

the

 

plug

 

relay

 

on,

 

the

 

timer

 

in

 

plug

 

start

 

run 

with

 

time

 

period

 

defined

 

in

 

parameter

 

#9

 

and

 

the

 

plug

 

will

 

turn

 

the

 

relay

 

off. 

Function:

 

​​

Time

 

switch

 

Configure 

Parameter

 

Number:

 

​​

8. 

Parameter

 

Size:

 

​​

1

 

Byte 

Available

 

Settings

:

 

0,

 

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

0

 

 

Time

 

switch

 

Disable. 

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

​​

 

1

 

 

Time

 

switch

 

Enable. 

Default

 

Setting:

 

​​

9.

 

Configure

 

Time

 

switch

 

Period 

This

 

parameter

 

defines

 

the

 

period

 

that

 

plug

 

time

 

switch

 

off.

 

This

 

parameter

 

can

 

be 

configured

 

1

 

~

 

65535(in

 

minutes).

 

If

 

Parameter

 

#9

 

is

 

set

 

to

 

‘1’,

 

and

 

relay

 

is

 

turn

on,

 

the 

relay

 

will

 

be

 

turn

off

 

after

 

delay

 

this

 

parameter. 

Function:

 

​​

Time

 

switch

 

Configure 

Parameter

 

Number:

 

​​

9. 

Parameter

 

Size:

 

​​

2

 

Byte 

Available

 

Settings

​:​

 

1

 

~

 

65535(minutes). 

Default

 

Setting:

 

​​

150(min) 

10.

 

Button

 

On/Off

 

Enable 

This

 

parameter

 

defines

 

the

 

button

 

on/off

 

function

 

is

 

enabled

 

or

 

not

 

on

 

the

 

top

 

of

 

the 

wall

 

plug.  

This

 

parameter

 

can

 

be

 

configured

 

0

 

and

 

1.

 

If

 

this

 

parameter

 

is

 

set

 

to

 

‘1’,

 

users

 

can

 

turn 

on

 

and

 

off

 

the

 

wall

 

plug

 

by

 

pressing

 

the

 

button

 

on

 

the

 

top

 

of

 

the

 

wall

 

plug.

 

If

 

this 

parameter

 

is

 

set

 

to

 

‘0’,

 

the

 

wall

 

plug

 

cannot

 

be

 

turned

 

on

 

and

 

off

 

by

 

pressing

 

the

 

button. 

Function:

 

​​

Enable

 

Button

 

On/Off 

Summary of Contents for STW-W3350WU

Page 1: ...nual Power plug Model number STW W3350WU Thank you for your support Please read the instruction manual carefully before operating Please keep the instruction manual for future reference Siterwell Technology HK Co LTD ...

Page 2: ...rnately every 300 milliseconds Please get familiar with the terms below before starting the operations This Plug has function that remembers the relay states the plug will turn on after power up next time if the plug is turn on before the power cut off Manufacture ID 0x0266 Product ID 0x1087 EU Technical Parameters ON OFF control Compatible with 300 series and 500 series Measuring voltage current ...

Page 3: ...controller or gateway operating manual 3 Press the button three times within 1 5 second the device will enter exclusion mode And the LED will flash on and off with yellow alternately five times within 2 seconds Note If device has not been added to Z wave network the device will enter adding mode automatically when it is powered on You should let the controller enter adding mode first before power ...

Page 4: ...rgy consumption measuring These measurement results are sent to Z Wave Controller or Z Wave Gateway Voltage The Supply Power Voltage For Plug Current The Current for the Electric Device Connect to Plug Consumption Power Power Consumed by an Electric Device in an Instant unit Watt W Energy Energy Consumed by an Electric Device in a Period Most commonly Measure in Kilowatt hours kWh One kilowatt hou...

Page 5: ...OWER_MANAGEMENT_OVER_LOAD_DETECTED to associated devices in lifeline Red Led will blink every second until current is normal less than Parameter 3 You must remove the loader and turn on the Plug press the button once to enable current monitor and clear NOTIFICATION ALARM This parameter value must be greater than 4 If user set this parameter to default by Configure CC the parameter 4 will be set to...

Page 6: ...r defines the timer function Enable Disable This parameter can be configured with 0 or 1 where 0 means disable time switch function and 1 enable The period will be defined in parameter 9 If this parameter is Set to 1 and when turn the plug relay on the timer in plug start run with time period defined in parameter 9 and the plug will turn the relay off Function Time switch Configure Parameter Numbe...

Page 7: ...ting This configuration is not influenced to OCP monitor and energy accumulated Function Meter Enable Parameter Number 12 Parameter Size 1 Byte Available Settings 0 1 Default Setting 1 LED Color Indicator LED Color Led Display Status Description Pink Blink 5 Times 1s Interval Power on or Reset and Not Add in Z Wave Network Blink 5 Times 500ms Interval Send Node Info when Press Button tripled Blue ...

Page 8: ...CH_ALL V1 COMMAND_CLASS_BASIC V1 SPECIFICATIONS Power Supply AC110 230V 10 50 60Hz Rate Load Current 13A 110 230V 50 60Hz Continuous Load 16A 110 230V 50 60Hz Momentary Load Power Consumption 0 13W EU Standards Compliance Radio Protocol Z Wave Radio Frequency EU 868 4MHz US 908 4MHz Valid Range Up to 60m outdoors Up to 30m indoors Depending on terrain and building structure Operational Temperature...

Reviews: