CC
to
trigger
over
current
protection.
If
you
set,
the
wall
plug
will
send
NOTIFICATION_EVENT_POWER_MANAGEMENT_OVER_LOAD_DETECTED
to
lifeline,
and
the
wall
plug
will
be
turn
off,
red
Led
will
blink
every
second.
You
can
press
the
button
once
to
clear
this
alarm
and
then
the
wall
plug
will
be
back
to
normal
state.
Advanced
Configuration
1.
Send
Meter
Report
Enable.
This
parameter
defines
Disable/Enable
meter
report
measure
data
to
controller.
This
setting
is
not
influenced
configuration
No.
6.
Function:
Meter
Report
Enable
Parameter
Number:
1.
Parameter
Size:
1
Byte
Available
Settings
:
0,
1.
0
–
Disable
Report
1
–
Enable
Report
Default
Setting:
1.
2.
Meter
Report
Interval
This
parameter
defines
interval
time
(in
seconds)
that
Meter
report
data
to
main
controller.
Function:
Set
Report
Interval
Parameter
Number:
2.
Parameter
Size:
2
Byte
Available
Settings
:
1
–
65535(s).
Default
Setting:
300(s)
3.
Configure
maximum
over
‐
load
current.
This
parameter
defines
maximum
current
the
plug
can
provide
to
load
that
be
connected
to
plug.
If
the
current
consumed
by
load
is
greater
than
maximum
current,
the
plug
will
cut
off
power,
and
send
NOTIFICATION_EVENT_POWER_MANAGEMENT_OVER_LOAD_DETECTED
to
associated
devices
in
lifeline.
Red
Led
will
blink
every
second
until
current
is
normal
(less
than
Parameter
#3).
You
must
remove
the
loader
and
turn
on
the
Plug
(press
the
button
once)
to
enable
current
monitor
and
clear
NOTIFICATION
ALARM
.
This
parameter
value
must
be
greater
than
#4.
If
user
set
this
parameter
to
default
by
Configure
CC,
the
parameter
#4
will
be
set
to
default
value.
Function:
Set
the
upper
current
threshold.
Parameter
Number:
3.
Parameter
Size:
1
Byte
Available
Settings
:
1
–
16
(Ampere).
Default
Setting:
13(A).
4.
Configure
maximum
Alarm
current.
This
parameter
defines
maximum
current,
if
the
current
plug
provide
to
load
is
greater
than
this
parameter,
the
plug
will
light
yellow
LED,
but
plug
cannot
cut
‐
off
power.
This
parameter
value
must
be
less
than
parameter
#3.
If
user
set
this
parameter
to
default
by
Configure
CC,
the
parameter
#3
will
be
set
to
default
value.
Function:
Set
Alarm
upper
current
threshold.
Parameter
Number:
4.
Parameter
Size:
1
Byte
Available
Settings
:
1
–
Parameter
#3
(Ampere).
Default
Setting:
12(A).
5.
Led
Display
Enable
This
parameter
defines
the
LED
indication
Function
ON/OFF.
This
parameter
can
be
configured
with
0
or
1,
where
0
means
disable
LED
indication
Function
and
will
always
be
turn
‐
off,
and
1
means
enable
LED
Function.
Function:
LED
Enable/Disable
Parameter
Number:
5.