background image

 

 

 

 

Instruction

 

Manual 

 

Power

 

plug 

Model

 

number:

 

STW-W3350WU 

 

Thank

 

you

 

for

 

your

 

support 

 

Please

 

read

 

the

 

instruction

 

manual

 

carefully

 

before

 

operating 

Please

 

keep

 

the

 

instruction

 

manual

​​

 

​​

for

 

future

 

reference 

 
 

 

 

 

 

Siterwell

 

Technology

 

HK

 

Co.,

 

LTD 

 
 
 

Summary of Contents for STW-W3350WU

Page 1: ...nual Power plug Model number STW W3350WU Thank you for your support Please read the instruction manual carefully before operating Please keep the instruction manual for future reference Siterwell Technology HK Co LTD ...

Page 2: ...rnately every 300 milliseconds Please get familiar with the terms below before starting the operations This Plug has function that remembers the relay states the plug will turn on after power up next time if the plug is turn on before the power cut off Manufacture ID 0x0266 Product ID 0x1087 EU Technical Parameters ON OFF control Compatible with 300 series and 500 series Measuring voltage current ...

Page 3: ...controller or gateway operating manual 3 Press the button three times within 1 5 second the device will enter exclusion mode And the LED will flash on and off with yellow alternately five times within 2 seconds Note If device has not been added to Z wave network the device will enter adding mode automatically when it is powered on You should let the controller enter adding mode first before power ...

Page 4: ...rgy consumption measuring These measurement results are sent to Z Wave Controller or Z Wave Gateway Voltage The Supply Power Voltage For Plug Current The Current for the Electric Device Connect to Plug Consumption Power Power Consumed by an Electric Device in an Instant unit Watt W Energy Energy Consumed by an Electric Device in a Period Most commonly Measure in Kilowatt hours kWh One kilowatt hou...

Page 5: ...OWER_MANAGEMENT_OVER_LOAD_DETECTED to associated devices in lifeline Red Led will blink every second until current is normal less than Parameter 3 You must remove the loader and turn on the Plug press the button once to enable current monitor and clear NOTIFICATION ALARM This parameter value must be greater than 4 If user set this parameter to default by Configure CC the parameter 4 will be set to...

Page 6: ...r defines the timer function Enable Disable This parameter can be configured with 0 or 1 where 0 means disable time switch function and 1 enable The period will be defined in parameter 9 If this parameter is Set to 1 and when turn the plug relay on the timer in plug start run with time period defined in parameter 9 and the plug will turn the relay off Function Time switch Configure Parameter Numbe...

Page 7: ...ting This configuration is not influenced to OCP monitor and energy accumulated Function Meter Enable Parameter Number 12 Parameter Size 1 Byte Available Settings 0 1 Default Setting 1 LED Color Indicator LED Color Led Display Status Description Pink Blink 5 Times 1s Interval Power on or Reset and Not Add in Z Wave Network Blink 5 Times 500ms Interval Send Node Info when Press Button tripled Blue ...

Page 8: ...CH_ALL V1 COMMAND_CLASS_BASIC V1 SPECIFICATIONS Power Supply AC110 230V 10 50 60Hz Rate Load Current 13A 110 230V 50 60Hz Continuous Load 16A 110 230V 50 60Hz Momentary Load Power Consumption 0 13W EU Standards Compliance Radio Protocol Z Wave Radio Frequency EU 868 4MHz US 908 4MHz Valid Range Up to 60m outdoors Up to 30m indoors Depending on terrain and building structure Operational Temperature...