1:  Do  not  use  an  open  flame  to  test  the  alarm.  You  may  ignite 

and damage the alarm or your home.   

2:  Test  the  alarms  weekly  and  upon  return  from  vacation  or 

when no one has been at home for several days. 

3: Stand at an 

arm’s length from the 

unit when testing. 

Test all smoke alarms weekly by doing the following step. 

4: Firmly press the test button for at least 5 seconds. The alarm 

will sound 3 short beeps 

 1.5 seconds pause, then repeat it 

until release the button. The alarm may sound for up to a few 

seconds after releasing the test button. 

DANGER: 

If  the  alarm  sounds,  and  it  is  not  being  tested,  it 

means  the  unit  is  sensing  smoke, 

THE SOUND OF THE ALARM 

REQUIRES YOUR IMMEDIATE ATTENTION AND ACTION.   

Wireless function description:   

Wireless frequency: 

433MHz 

Operation current

:   

RF Receiver: 

<5mA

 

RF emitter: 

<10mA 

Wireless distance:

 >20 meters 

Note: Make sure the battery is installed well before operating the 

product.

 

1: Send wireless coding mode       

a: 

Press  and  hold  the  test  button  on  the  alarm  until  the  red 

LED  light  about  1S,  release  the  button,  the

  alarm 

enters 

into  the  wireless  coding  sending  status.  The  LED  is 

always  ON.  If  you  press  the  test  button  or  have  not 

wireless learning signal within 30 second, the LED will be 

OFF. 

    Note: enter this mode from standby status, press and hold 

the button for about 12 seconds required.

 

b: When there are other alarms received in response to this 

wireless coding command, the red LED flashes for about 2 

seconds. Then re-enter the wireless coding sending status, 

waiting for the next alarm response. If there is no alarm 

response to this command within 30 seconds, the unit will 

exit automatically. 

   

2: Learning mode       

a:  Press  the  test  button  of  the  alarm,  the  red  LED  light  1 

second,  then  release  the  button  immediately,  the  alarm 

enters  into  learning  mode.  Note:  There  must  have  other 

alarms  in  the  "Send  Wireless  coding  mode",  this  alarm 

will be able to enter into the learning mode. 

 

b:  If  the  learning  is  successful,  the  red  LED  flashes  for 

about  2  seconds,  then  exit  the  learning  mode 

automatically.

 

     

3: Clear code mode     

a

: Press and hold the test button on the alarm until the red 

LED flashes for about 1 second, release the button, the 

alarm enters the clear code mode. Note: enter this mode 

from standby mode, press and hold the button for about 

16 seconds required. 

 

b: After releasing the button, press the button when the red 

LED  lights  up,  release  the  button  when  the  red  LED  is 

off, if you hear the sound of `BI` sound after two cycles, 

that  indicates  clear  code  is  success,  the  alarm  own 

wireless code and the wireless code learned will be reset 

to the new code, the new code is random.

 

4: How to match each other smoke alarm     

a:

 Take one alarm to enter into "send wireless coding mode".   

b: Take another alarm into learning mode, when the red LED 

flashes  for  2  seconds,  which  means  that  the  learning 

success.   

c: Follow steps b to complete the all alarms.   

d:  Press  the  test  button,  exit  the 

  send  wireless  coding 

mode

. The red LED is OFF. Wait for about 30 seconds. 

e: Take one alarm, press the test button and hold for about 30 

seconds. If other alarms all enter into the wireless alarm 

status. That indicates a successful match. 

Maintenance and Cleaning: 

In  addition  to  weekly  testing,  the  alarm  requires  periodic 

cleaning to remove dust, dirt, and debris. 

Clean  the  alarm  at  least  once  a  month  to  remove  dust,  dirt,  or 

debris.   

Use a vacuum cleaner with the soft brush, vacuum all sides and 

covers of smoke alarm. Be sure all the vents are free of debris. 

IMPORTANT:  Do  not  attempt  to  remove  the  cover  to  clean 

inside. This will affect warranty. 

WARNING!  Use  only  the  batteries  specified.  Use  different 

batteries may have detrimental effects on the alarm. A good 

safety measure is to replace the battery at least once a year.   

Note: Reinstall immediately after cleaning and then test unit 

using the test button. 

Repair: 

Caution:  Do  not  attempt  to  repair  the  alarm.  It  will  affect  your 

warranty. 

If the alarm is not operating properly, and is still under warranty, 

return  it to  the original place  you buy.  Pack it in  a  well-padded 

carton, and ship to the original place you buy.   

If  the  alarm  is  no  longer  under  warranty,  have  a  licensed 

electrician replace it immediately with a comparable alarm. 

Practice Fire Safety: 

If the alarm sounds, and you have not pushed the test button, it is 

warning  of  a  dangerous  situation,  your  immediate  response  is 

necessary.  To  prepare  for  such  occurrences,  develop  family 

escape  plans,  discuss  them  with  all  household  members,  and 

practice them regularly. 

Summary of Contents for GS558A

Page 1: ... smoke alarm on the basement ceiling at the bottom of the stairwell Typical multi storey dwelling with recommended protection Install a smoke alarm on the ceiling inside each bedroom and in the hallway outside each separate sleeping area If a bedroom area hallway is more than 30 feet long install a smoke alarm at each end install a smoke alarm at the top of a first to second floor stairwell Import...

Page 2: ... alarm using test button The sound pattern is 3 short beeps 1 5seconds pause repeat it If there s no sound output it means that the smoke alarm is faulty or the installing operation is wrong and you should gain the correctly method of disposal through reading TROUBLE SHOOTING NOTE During testing because the unit send the wireless signal may the other smoke detector will alarm Once release the test...

Page 3: ...s for about 1 second release the button the alarm enters the clear code mode Note enter this mode from standby mode press and hold the button for about 16 seconds required b After releasing the button press the button when the red LED lights up release the button when the red LED is off if you hear the sound of BI sound after two cycles that indicates clear code is success the alarm own wireless c...

Page 4: ...product In no case shall company be liable for any incidental or consequential damages for breach of this or any other warranty express or implied whatsoever The bad product can be mailed to the following address with a detail explanation of problem Before you install the alarm please read the instruction Where is the best to be Installed At first you need install one unit in the bedroom and route...

Page 5: ... well on the bracket Test smoke alarm using test button The alarm will sound 3 short beeps 1 5 seconds pause then repeat it until release the button if no sound it indicates a defective alarm you can refer to Trouble shooting for solution or return to your retailer during warranty If you have any questions on installation you can contact your retailer During testing may the other smoke detector wi...

Reviews: