![Sita IT Series Manual Of Installation, Use And Servicing Download Page 15](http://html.mh-extra.com/html/sita/it-series/it-series_manual-of-installation-use-and-servicing_1285532015.webp)
14
● Each lamps has 2 wires connected from the top to the bottom .Lamps must be inserted into the
chamber with these wires in the opposite side to the sensor.
To do this the two pins (signed with the red circle in the photo below) must be in the opposite side to
the sensor.
●
Connect to the UV-C lamps the 4-pins connectors (E) mounted as on the figure together with the Ø 1
¼” ring nuts (F), the PG9 nipples (G), and the 4-pins holders in black polyethylene (H) with the
pertinent o-rings 2112 type.