45
PARAMETERS
SCREEN
Programs : 1 Readings: 2 Erasure: 3
Parameters: 4 Manual: 5 Clock: 6
FUNCTION
PARAMETERS Fertiliza.: 1 Cleaning: 2
Generals: 3 Sensors: 4 Flows: 5
PARAMETERS Sectors: 6 Programs: 7
Communica.: 8 Various: 9
Fertilizer parameters
1
Number of fertilizers ( 0 – 8 ): 4
Fertilization series(1) parallel (2) uniform(3): 2
Proportional fertilization ( Y/N ): YES
Fertilizers end cleaning: 018”
Mixer 1
Pre-mixing: 025”
Start / stop mixing: 015”/120”
Mixer 2
Pre-mixing: 025”
Start / stop mixing: 000”/001”
Mixer 3
Pre-mixing: 000”
Start / stop mixing: 000”/000”
Mixer 4
Pre-mixing: 000”
Start / stop mixing: 000”/000”
- pH CONTROL OPTION -
pH alarm= (+) 0.6 pH ( - ) 0.4 pH
Detection delay: 038”
Detection delay alarm 100%: 025”
EC alarm= (+) 02.1 mS ( - ) 00.8 mS
Detection delay: 105”
Inject for base ( 1 ) acid ( 2 ): 2
Modulation cycle: 2.5”
Proportional band: 2.0
Reaction: 1
Apply acid in pre-irrigation: NO
Apply acid in post-irrigation: YES
Filter cleaning Parameters
2
Filter group number: 1
Cleaning time: 134” subg. 1: 01 a 01
Cleaning time: 108” subg. 2: 02 a 05
Pause time between filters: 04”
Units between cleanings: 02300
Stop sectors when cleaning: Y.
Maximum num. of cleanings: 3
In relation to M 1 2 3 4 C 1 2 3 4
Y Y
N
N Y
Y
N
N
-->
Fert. cleaning F7 F8
Output number: 00000000 00000000
Auxiliary Fert. F1 F2
Output number: 00000091 00000092
- - - - - - - - -
Auxiliary Fert. F7 F8
Output number: 00000000 00000000
Analog output F1 F2
Output number: 00000001 00000002
- - - - - - - - -
Analog output F7 F8
Output number: 00000000 00000000
General fert. output: 00000080
Filters G1: 00002161 to 00002165
Filters general G1: 00000089
Alarm 1 2 3
Output : 00000000 00000000 00000000
Start/stop temporization alarm: 008”/030”
Normally open alarm (Y/N): NO
- pH CONTROL OPTION -
pH control general output: 00000091
pH analog output: 00000009
Pump 4
Output number: 00000000
On/off temporization: 000” / 000”
Fertilizers F1 F2
Output number: 00000084 00000085
- - - - - - - - -
Fertilizers F7 F8
Output number: 00000084 00000085
Mixers F1 F2
Output number: 00000087 00000088
- - - - - - - - -
Mixers F7 F8
Output number: 00000000 00000000
Fert. cleaning F1 F2
Output number: 00000087 00000088
- - -
- - -
- - -
---->
Pump 3
Output number: 00002201
On/off temporization: 004” / 004”
On/off temporization: 020” / 012”
Pump 2
Output number: 00000083
Pump 1
Output number: 00000082
On/off temporization: 005” / 018”
General outputs parameters
3
hh:mm (0) mm’ss” (1) L (2) dl (3) cl (4): 2
Irrigation meter 1
Nominal flow margin high/low: 10 / 08 %
Irrigation meter 2
Nominal flow margin high/low: 12 / 12 %
Irrigation meter 3
Nominal flow margin high/low:: 12 / 12 %
Irrigation meter 4
Nominal flow margin high/low: 00 / 00 %
Detection delay: 280”
Stop type, NO (0) Tem. (1) Def. (2): 1
Irrigation start delay: 033”
Flow parameters
5
Irrigation units =
hh:mm (0) mm’ss” (1) m
3
(2) L(3): 2
Fertilization units =
- PRESSURE REGULATION OPTION -
Pressure regulation prop. band: 1.2
Pressure regulation reaction: 1
Analog out. Pressure Reg.: 00000003
-
DIESEL CONTROL OPTION -
Starting output: 00000070
Stop output: 00000071
Contact output: 00000072
Pre-heating output 00000000
Time of starting: 04”
Time between attempts: 015”
Time of pre-heating: 000”
Time of stop: 035”
Time between starting and pump: 150”
Time between pump end and stop: 200”