sisel ENDA ET2413K Quick Start Manual Download Page 3

OUTPUT GRAPHICS

TRANSFERRING THE PARAMETERS FROM ENDAKEY TO DEVICE

While in "Running Mode",           if key is pressed on device, “ 

uL

 ” message 

appears  on  display  and        key  is  pressed  again,  parameters  are  read  and 
transferred to the device. If process succes, “ 

5uc

 ” message appears. In case 

of failure, " 

Err

 " message displayed and parameters will not be changed on 

device.

TRANSFERRING THE PARAMETERS FROM DEVICE TO ENDAKEY

NOTE  1  :

  No  power-up  required  for  transfering  the  parameter  by  using 

"ENDAKEY".  For  long  battery  life,  "ENDAKEY"  must  be  disconnected  from 
device after the transferring process.

NOTE 2 :

 Please specify at order “ENDAKEY” if required.

Read

button

While in "Running Mode", if      key on device or  “Read”  button on “ENDAKEY” 
is  pressed,  “ 

dL

  ”  message  appears  on  display.  While  " 

dL

  "  message 

displayed  on  device  and  if        key  is  pressed,  parameter  values  from 
"ENDAKEY” transferred to the device. If the parameter transfer is successful, 
the " 

rEf

 " message appears and the device begins to work with the loaded 

parameter values. If the parameters are wrong, incorrect or " ENDAKEY " is 
failure,   " 

Err

 " message appears and parameters will not be changed on 

device.

HEAT
 

   (Temperature)

output

ROTATION

INDICATOR

LED

Power

r.int

r.dur

SET

SET+ 

r.HYS

SET- 

r.HYS

  

HE

 

control

(heating)

Rotation

 

 

mod

e

Humidification

Mode

The time between two consecutive rotating operations

Rotation duration  (If 

r.dur

=

0

 is selecled, automatic and manual rotating is disabled.)

 ROTATION

OUTPUT

h.int

h.dur

Time between two consecutive humidifications

Humidification duration  (If  

h.dur

=

0

  is selected, humidification is disabled.)

ROTATION (CYCLE) OUTPUT GRAPHICS

HUMIDIFICATION OUTPUT GRAPHICS

HEATING OUTPUT GRAPHICS

Rotation

 

 

mod

e

HUMIDIFICATION

INDICATOR

LED

HUMIDIFICATION

OUTPUT

LoL

uPL

-60.0   

   

°C

     -60              

uPL

  

LoL

  

 

 150.0

  

     

°C

 

          

150

HY5
oFF

       

20.0

   

     

°C        

        

2

 

         

  

20.0 

  

    

°C        

       

0

 

     

0.1

   

 

-20.0

Min.

Max.

UNIT

DEFAULT

VALUE

Unit

           

   

°F

                  

           

°C

    

°C

Dpnt

YE5

  

YE5

          

No

 

CONFIGURATION PARAMETERS

Upper limit for setpoint 

Heating differential  (hysteresis)
Offset value for heating

CONTROL PARAMETERS 

Lower limit for setpoint 

Temperature unit

Decimal point (

no

= decimal point isn’t shown 

22

°

C,

YE5

=decimal point is shown 

22.3

°

C.)

r.dur

r.int

               99:00                        

    

 

 

       

 

99:00

    

min:sec

      

 

 

     0:00

ROTATION CONTROL PARAMETERS

Rotating duration  ( If  

r.dur

 

0

 selected, automatic and manual rotation is disabled ).

Time between 2 consecutive rotation.

1:00

1:00

hr:min

     0:00

h.dur

h.int

               99:00                        

    

 

 

       

 

99:00

    

min:sec

      

 

 

     0:00

HUMIDIFICATION CONTROL PARAMETERS

Humidification duration  ( If  

h.dur

 

0

 selected, automatic and manual humidification is disabled ).

Time between 2 consecutive humidification.

1:00

1:00

hr:min

     0:00

3

/3

      ET2413K-

EN

-01-17032

7

ENDA

TM

SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.

Şerifali Mah. 

 Y.Dudullu  34775

ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx.    Fax : +90 216 365 74 01
url : www.enda.com.tr

Barbaros Cad. No:18