ERROR MESSAGES
P
5
C
Pfa
5. Changing Parameter Values
4. Activating / Inactivating The Control Outputs
C.dI
5
C
E
NB
When in the "Running mode", if key is pressed for 2 seconds,
C.dI5
message is displayed and control outputs becomes to the inactive position, the device
works as the indicator. When the control outputs are disabled; if key is pressed for 2 seconds
C.EnB
is disabled and the device continues to control function.
If keys are pressed together for 2 seconds “User Menu” is entered, then first parameter’s name is displayed in the user menu.
While a parameter is selected, by pressing key, parameter value can be displayed. This parameter can be changed with keys. If no operation
performed for 3 seconds or during this time, key is pressed while parameter value displayed, parameter name will be displayed again. While parameter name
displayed, if by pressing together keys, "Running Mode" is entered.
1000
-
24.0
The control ouput becomes inactive.
The control output becomes active.
SET
SET
NTC probe is broken or not connected.
Temperature value is higher than the scale.
NCT probe is short circuit.
Temperature value is lower than the scale.
FACTORY SETTINGS
If key is held down while the device is powered up,
d.PAr
message appears and factory parameters restored.
ROTATION
LED
:
Lights up while rotating process.
SET
FAHRENHEIT LED :
In parameter value or the measured temperature value “
°
F”
unit while this LED
lights up. In the hidden menu at the same time the user menu parameter is shown the LED lights up.
HEAT LED :
Lights up while heating (heat output is active).
In "Running Mode", indicates the set value.
In “Programming Mode”, indicates the selected parameter value.
While in "Programming Mode", provides the transition to the next parameter. If parameter is being
adjusted, it increases parameter’s value. Constantly holding this key, the parameter value rapidly
increases.
While in "Programming Mode", provides the transiton to the previous parameter. If parameter is
being adjusted, it decreases parameter’s value. Constantly holding this key,the parameter value
rapidly decreases.
HUMIDIFIER LED
:
Lights up while humidifying process.
FRONT PANEL COMMANDS
1. Viewing and Changing The Set Value
Measurement
value
-
30.0
-
29.9
-
30.0
1000
-
24.0
SET
While in "Running Mode", if key is pressed set value is displayed for 3 seconds. While in this case, the set value is changed with keys.
SET
Loc
unl
1000
-
24.0
SET
Keys are locked.
Keys are unlocked.
SET
SET
SET
SET
While in "Running Mode", if keys are pressed together for 2 seconds,
Loc
message is displayed and the keys are locked. If the keys are locked
keys are pressed for 2 seconds again,
unL
message is displayed and keys are unlocked. While keys are locked and if key is pressed, set value can be
displayed but can not be changed. While the keys are locked and if any key is pressed
( except key )
,
Loc
message appears.
2. Locking and Unlocking Keys
3. Manuel Rotating Process
While in the "Running Mode", if key is pressed for 2 seconds, defrost process starts manually. If
parameter is
0
, manual defrost will be inactive.
r.dur
°F
.
Measurement
value
Measurement
value
SET
SET
ET2413K
ENDA
°C
°F
RH
RH
2
/3
ET2413K-
EN
-01-17032
7
ENDA