sisel ENDA ET2413K Quick Start Manual Download Page 2

TM

ERROR MESSAGES

 

  

P

5

C

 Pfa

5. Changing Parameter Values

 4. Activating / Inactivating The Control Outputs

    

    

    

C.dI

5

C

E

NB

 When in the "Running mode", if        key is pressed for 2 seconds, 

C.dI5

 message is displayed and control outputs becomes to the inactive position, the device 

works as the indicator. When the control outputs are disabled; if       key is pressed for 2 seconds  

C.EnB

   is disabled and the device continues to control function.          

       

If          keys are pressed together for  2 seconds “User Menu” is entered, then first parameter’s name is displayed in the user menu.

While a parameter is selected, by pressing         key, parameter value can be displayed. This parameter can be changed with            keys. If no operation 
performed for 3 seconds or  during this time,       key is pressed while parameter value displayed, parameter name will be displayed again. While parameter name 
displayed, if by pressing together           keys, "Running Mode" is entered. 

1000

-

24.0

The control ouput becomes inactive.

The control output becomes active.

SET

SET

NTC probe is broken or not connected.

 Temperature value is higher than the scale.

NCT probe is short circuit.

Temperature value is lower than the scale.

FACTORY SETTINGS

If      key is held down while the device is powered up, 

 

d.PAr

 message appears and factory parameters restored.

                

ROTATION

 LED

 

:

 

Lights up while rotating process.

SET

FAHRENHEIT LED : 

In parameter value or the measured temperature value “

°

F”

 unit while this LED 

lights up. In the hidden menu at the same time the user menu parameter is shown the LED lights up.

                

HEAT LED : 

Lights up while heating (heat output is active).

In "Running Mode", indicates the set value.
In “Programming Mode”, indicates the selected parameter value.

                

While in "Programming Mode", provides the transition to the next parameter. If parameter is being 

              adjusted, it increases parameter’s value. Constantly holding this key, the parameter value rapidly
              increases.

While in "Programming Mode", provides the transiton to the previous parameter. If parameter is
being adjusted, it decreases parameter’s value. Constantly holding this key,the parameter value
rapidly decreases.

                

HUMIDIFIER LED 

:

 

Lights up while humidifying process.

 

 FRONT PANEL COMMANDS

1. Viewing and  Changing The Set Value

Measurement 

value

-

30.0

-

29.9

-

30.0

1000

-

24.0

SET

While in "Running Mode", if         key is pressed set value is displayed for 3 seconds. While in this case, the set value is changed with          keys.

SET

Loc

unl

1000

-

24.0

SET

Keys are locked.

Keys are unlocked.

SET

SET

SET

SET

While in  "Running Mode", if             keys are pressed together for 2 seconds, 

 

Loc

 message is displayed and the keys are locked. If the keys are locked

             keys are pressed for 2 seconds again, 

unL

 message is displayed and keys are unlocked. While keys are locked  and  if       key is pressed, set value can be 

displayed but can not be changed. While the keys are locked and if any key is pressed 

( except        key )

,  

Loc

  message appears.

 2. Locking and Unlocking Keys

 3. Manuel Rotating Process

While in the "Running Mode", if       key is pressed for 2 seconds, defrost process starts manually. If   

parameter is 

 

0

 , manual defrost will be inactive.         

r.dur 

°F

.

Measurement 

value

Measurement 

value

SET

SET

 ET2413K

ENDA

°C

°F

RH

RH

2

/3

      ET2413K-

EN

-01-17032

7

ENDA

TM

SİSEL MÜHENDİSLİK ELEKTRONİK SAN. VE TİC. A.Ş.

Şerifali Mah. 

 Y.Dudullu  34775

ÜMRANİYE/İSTANBUL-TURKEY
Tel : +90 216 499 46 64 Pbx.    Fax : +90 216 365 74 01
url : www.enda.com.tr

Barbaros Cad. No:18