22
SECTION 15: SERVICING
Isolate the fire from the gas supply.
Ensure that the fire is fully cold before attempting service.
A suggested procedure for servicing is detailed below:
1. Lay out the dust sheet and tools required.
2. Remove the fascia, see Section 9.
3. Carefully remove the ceramic components
4. Remove the four screws that retain the burner tray in place and disconnect from the
isolation tap.
5. Remove the burner tray and other components as required (i.e. remote control box)
6. Disconnect the gas supply, to the appliance and disconnect the isolation tap
7. If required remove flue liner adaptor and fire box.
8. Check the fireplace opening for rubble accumulation and remove, if debris is excessive,
initiate remedial work on the flue.
9. Check the flue with smoke pellet for correct operation.
10. Refit Fire box and gather hood using new seals where necessary
11. Strip off the burner pipes and clean thoroughly.
12. Clean out the injector, pilot assembly and burner tube. DO NOT remove the pilot injector.
13. Re-assemble and re-fit the burner tray.
14. Turn on the gas supply, and leak test.
15. Refit the decorative fuel bed and ceramics.
16. Check any purpose provided ventilation is un-obstructed.
17. Light the fire and test for spillage.
18. Check setting pressure and safe operation of the appliance.
Summary of Contents for Royal Solo Apex
Page 38: ...38 SECTION 20 LIST OF SPARES Royal 600 Manual Controls C1 C 4 C2 C3 B1 ...
Page 39: ...39 SECTION 20 LIST OF SPARES Royal 1000 Manual Controls A5 A6 A4 A7 C1 C 4 C2 C3 B1 ...
Page 40: ...40 Royal 400 Remote Control A5 A6 A4 A7 C1 C 4 C2 C3 ...
Page 41: ...41 Royal 600 Remote Control A2 A3 A4 A1 A2 A3 A1 A4 ...
Page 42: ...42 Royal 1000 Remote Control 5E 2E 3E 4E 6E 13E 10E 12E 7E 11E A1 A2 A3 A4 ...
Page 43: ...43 Royal 400 Ceramics Royal 600 Ceramics Royal 1000 Ceramics F1 F3 F5 ...