To install the appliance please respect the follow 
instructions:
•  The appliance must be installed by qualified 

technicians, or where possible use a Sirius 
recommended installer. See siriusbrand.com. In 
order to avoid damage to the electronic parts 
of the appliance, please do not use additional 
screws.

•  Essential precautions to respect before installing 

the appliance are the following:  
To have made a cutout on the bottom of the 
cabinet which is suitable to hold the appliance in 
position (fig. 4): 

SL906 DL 520

 - 501 x 265mm 

SL906 DL 850

 - 835 x 265mm 

SL906 DLTM 850 

- 835 x 265mm 

SL906 DLTM 1000

 - 985 x 265mm 

SL906 DLTM 1200

 - 1100 x 265mm 

SL906 DLTM 1500

 - 1480 x 364mm

SL906 DL series INSTALLATION - 
ONBOARD MOTOR

Before installing the appliance, make sure that 
none of the parts are damaged in any way. In 
case of damaged parts, contact your retailer 
and do not proceed with installation. Read all 
of the following instructions with care before 
installing the appliance. 

•  Use ducting within the min/max specifications
•  Limit the number of ducting bends.
•  Do not make any changes in ducting diameter 

(recommended constant diameter:  
Ø 150 mm / Ø 200 mm / Ø 300mm or equal 
surface area). 

Before installing the appliance - in order not to 
damage the appliance itself - the metal grease filter 
should be removed. These filters could be removed 
by pushing the handles towards the back side of the 
rangehood and pulling it downwards to unfasten it 
from its slot. (Fig.3).

NOTE

(Fig.3a)

(Fig.3b)

(Fig.4)

1.  Prepare the power supply - 240 volts.
2.  Prepare a hole for the exhaust - 160mm diameter 

for single motor & 210mm for twin motor versions 
and 310mm for triple motor version.

•  Do not use screws to fix the ducting to the 

rangehoods as they will prevent the movement of 
non-return valves.

•  Limit the number of elbows in the ducting, since 

each elbow reduces the duct efficiency by 1 
metre. (i.e. if you use two 90° elbows, the length 
of ducting must not exceed 5 metres.)

•  Avoid abrupt direction changes.
•  Use 150mm constant diameter ducting for the 

whole length for the single motor, 200mm ducting 
for the twin motor model, and 300mm for triple 
motor version.

•  The use of Sirius ducting 
•  will increase the warranty of the unit to 6 

years.

WARNING: Failure to install the screws or fixing 
device in accordance with these instructions 
may result in electrical hazards.

Summary of Contents for 9351116005061

Page 1: ...ratulations on your purchase Thank you for choosing a Sirius product SL906 DL 520 EAN 9351116005061 SL906 DL 850 EAN 9351116005078 SL906 DLTM 850 EAN 9351116005085 SL906 DLTM 1000 EAN 9351116005092 SL906 DLTM 1200 EAN 9351116005108 SL906 DLTM 1500 EAN 9351116005115 www siriusbrand com ...

Page 2: ... OF CONTENTS BEFORE YOU INSTALL INSTALLING THE RANGEHOOD OPERATION MAINTENANCE DIMMABLE LIGHT FUNCTION REPLACING THE LED STRIP WIRING DIAGRAM SINGLE MOTOR WIRING DIAGRAM TWIN MOTOR WARRANTY 3 5 7 7 7 8 9 10 11 ...

Page 3: ... service and parts Flexible ducting is not permitted under any circumstances Flexible ducting has been found to increase noise levels increase vibration and reduce airflow Sirius Semi rigid or solid ducting can be used in lieu There is a range available to suit any application Ducting available at www siriusbrand com 6 Year Warranty when Sirius Ducting is used Full replacement warranty on parts an...

Page 4: ...se make sure that the current tap is provided with earth connection and that voltage values correspond to those indicated on the label placed inside the appliance itself Before carrying out any cleaning or maintaining operations the appliance needs to be switched off If the appliance is not provided with a non separable When ducting rangehood options are as follows Roof vent EASYROOF 150T M EASYRO...

Page 5: ... any changes in ducting diameter recommended constant diameter Ø 150 mm Ø 200 mm Ø 300mm or equal surface area Before installing the appliance in order not to damage the appliance itself the metal grease filter should be removed These filters could be removed by pushing the handles towards the back side of the rangehood and pulling it downwards to unfasten it from its slot Fig 3 NOTE Fig 3a Fig 3b...

Page 6: ...he rangehood with the necessary strength to unhook the hood from the cabinet If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard 4 Insert the grease channel 5 Insert the grease filter Fig 3b Before connecting any ducting to the motor make sure the non return valves which are on the air outlet of the m...

Page 7: ...ries A Light switch on off B Motor switch on speed 1 off low simmer C Motor switch on speed 2 general cooking D Motor switch on speed 3 high power E Motor switch on speed 4 booster F 10 minute shut off timer OPERATION Fig 8 DIMMABLE LIGHT FUNCTION This function provides for lights dimmability ranging from 20 to 100 by holding down light key on the remote control or rangehood buttons Functions are ...

Page 8: ...opriate tools remove the LED light from its slot Fig 9a b 2 Take out the LED light from its connector and replace Fig 9c d To find the correct LED light please contact Sirius directly on our toll free number 1300 762 216 NB light is easier to remove from the centre of LED strip Use a small flathead screwdriver pallette knife or blunt butter knife ...

Page 9: ...9 WIRING DIAGRAM SL906 DL single motor ...

Page 10: ...10 WIRING DIAGRAM SL906 DLTM twin motor ...

Page 11: ... Sirius s Total Peace of Mind Protection Plan Australian New Zealand 3 6 Year Protection Plan This guarantees your appliance for a full 3 years parts and labour 10 years for the off board motors covering manufacturing defects only from the date of purchase subject to the Terms and Conditions overleaf 3 Year warranty is extended to a 6 year period only when Sirius ducting is installed Year Warranty...

Page 12: ...his warranty will not apply where a The fault is caused by accident misuse an infestation of insect and or vermin fire flood or the use of products not approved by Arisit Pty Limited b There has been a failure to comply with the manufacturer s operating and installation instructions c Service modification or repair has been carried out by anybody other than an approved Arisit Service Technician d ...

Reviews: