LINE MEASUREMENTS FOR MOUNTING HOLES

Fig.4c: 

SLT968EM

Fig.4e: 

SLT974EMEL

Fig.4f: 

SLT979EMEL

Fig.4a: 

SLT958EM

Fig.4b: 

SLT960EM

Fig.4d: 

SLT972EMEL

As every installation will differ slightly depending on the ceiling cavity of the dwelling,  

this installation shall be used as a guide only.

NOTE

•  These cassettes are held in place with the use 

of the 4 x 250mm threaded bolts. Using the 
measurements in the Fig. 4 line drawings ensure 
that there is timber framework (not supplied) inside 
the cavity to support the weight on the cassette. 
Please refer to each individual measurement for 
the exact location of the mounting holes or take 
a physical measurement of the location when the 
cassette has been unpackaged.

Summary of Contents for 9351116000455

Page 1: ...ulations on your purchase Thank you for choosing a Sirius product SLT958EM EAN 9351116001292 SLT958EMWH EAN 9351116001780 SLT960EM EAN 9351116000936 SLT968EM EAN 9351116002053 SLT968EMWH EAN 935111600...

Page 2: ...2...

Page 3: ...0 INSTALLING THE TIMBER SUPPORT BEAMS 11 MOTOR AND VENTING OPTIONS 12 TOP VENT INSTALLATION 13 SIDE VENT INSTALLATION SEM1 SEM11 SEM2 SEM21 14 SIDE VENT INSTALLATION SEM7 SEM71 SEM8 SEM81 15 REMOTE CO...

Page 4: ...service and parts Flexible ducting is not permitted under any circumstances Flexible ducting has been found to increase noise levels increase vibration and reduce airflow Sirius Semi rigid or solid du...

Page 5: ...ised technician Always disconnect the hood before carrying out cleaning or maintenance operations Adequately ventilate the room when a rangehood and other appliances powered by energy other than elect...

Page 6: ...two speeds operating Remove all plugs and proceed with installation if both unit and motor are fully operational Lighting connection Installation must comply with the regulations in force regarding th...

Page 7: ...y for service and parts Flexible ducting is not permitted under any circumstances Flexible ducting has been found to increase noise levels increase vibration and reduce airflow Sirius Semi rigid or so...

Page 8: ...LECTROCUTION The cassette requires one 10AMP GPO located inside the ceiling cavity to power both the lighting and the motor SLT960EM ONLY Installation of the ceiling cassette can either be installed 5...

Page 9: ...ted for safety purposes Step 1c On the side where the speed control light is visible pull down in the centre of the panel The panel is held on by a strong magnet Allow the panel to swing open to expos...

Page 10: ...on shall be used as a guide only NOTE These cassettes are held in place with the use of the 4 x 250mm threaded bolts Using the measurements in the Fig 4 line drawings ensure that there is timber frame...

Page 11: ...r is on the INSIDE OF THE CEILING CASSETTE Fig 5a Lift the cassette into position and ensure that the 4 x 250mm bolts pass through the mounting points Fit the larger diameter washer first and then win...

Page 12: ...oof vent option shown Motor can also be wall or eave vented Motor must not be more than 2 metres from ground for servicing access Roof flashing not supplied withe SEM5 Motor Please see Sirius ducting...

Page 13: ...K 1 K 2 SEM2 SEM21 SEM7 SEM71 MOTOR OUTSIDE INSIDE WALL INTERNAL MOTOR Ducting to SEM1 SEM11 150mm SEM8 SEM81 motor 200mm Please note that the final exit point for SEM1 SEM11 or SEM8 SEM81 can be thr...

Page 14: ...op of the 150mm connector piece Part H to the round outlet on adaptor Part A the connect length of 150mm ducting Part K 1 to the bottom of the 150mm connector piece Part H 2A Secure to the motor with...

Page 15: ...art E 1B Connect a duct expander Part G to round adapter then connect length of ducting Part K 2 to the 200mm outlet 2B Secure to the motor with a universal ring clamp Part G See page 12 for ducting t...

Page 16: ...els only This function provides for lights dimmability ranging from 20 to 100 by continuously pressing the Light ON OFF on the remote control Functions are the following Light ON or OFF shortly press...

Page 17: ...or by using Touch ID or Face ID The steps below don t apply to the iPhone 5c iPhone 5 iPhone 4s or the iPhone 4 1 Open the App Store To install apps you must sign in with your Apple ID or create one...

Page 18: ...or Archive folder If you didn t find yet please create another account 5 From Login page Insert the e mail and password of your account and tap LOGIN Fast way using the WPS procedure if your router h...

Page 19: ...you remove the grease filters 8 Press ACTIVATE DEVICE and you have a pop up message 8 Tap the device icon Enjoy your device 5 On your range hood Switch off completely light and motor Hold button for 3...

Page 20: ...NGS 4 ON YOUR RANGE HOOD Switch off completely light and motor Hold button for 3 secs for settings menu LEDs will flash press button to enable manual pairing Hold button for 3 sec button to save Note...

Page 21: ...21 6 Connect to HOOD network inserting as passwork password 7 CLICK BACK 8 ENTER WI FI NAME AND WI FI PASSWORD 9 TAP CONFIGURE 10 In case of following error Go back to the home page TAP Claim Devices...

Page 22: ...uct visible by removing the grease filters 12 Connect your mobile to your home Wi Fi Router network 13 Press ACTIVATE DEVICE and you have a pop up message 14 Tap the device icon Enjoy your device REMO...

Page 23: ...ing OFF BI POWER The BI POWER function allows reducing the performance of the fan if the maximum efficiency of the product is not required LIGHT Slide the toggle switch for switching ON OFF Slide the...

Page 24: ...24 RENAME DEVICE Tap on and rename device SHARE DEVICE Tap on and share device only to subscribed account...

Page 25: ...ette Maximum distance is 7 metres however 3 5 metres is optimum to minimise noise and maximise performance 3 Using another length of semi rigid duct run from the exit collar on the SEM1 SEM11 and SEM8...

Page 26: ...26 WIRING DIAGRAM SLT968EM...

Page 27: ...27 WIRING DIAGRAM SLT972EMEL SLT974EMEL SLT979EMEL...

Page 28: ...28 PART A Side vent adapter PART B Side vent cover PART C Top bracket PART D Front rear vent adaptor SPS 20059120071 PART E Front rear vent cover plate SPS 75059000082 PARTS LIST INCLUDED...

Page 29: ...ART G 150mm to 200mm Duct expander GDR 150 200 PART H 150mm diameter connector piece GDC 150 PART J 200mm diameter connector piece GDC 200 Part K 1 K 2 Semi rigid aluminium ducting 150mm 200mm SRPRO 3...

Page 30: ...30 NOTES...

Page 31: ...Sirius s Total Peace of Mind Protection Plan Australian New Zealand 3 6 Year Protection Plan This guarantees your appliance for a full 3 years parts and labour 10 years for the off board motors coveri...

Page 32: ...his warranty will not apply where a The fault is caused by accident misuse an infestation of insect and or vermin fire flood or the use of products not approved by Arisit Pty Limited b There has been...

Reviews: