22
Uplink
®
LTE30VZ Installation & User’s Guide
Uplink
®
LTE30VZ Installation & User’s Guide
Installation (cont.)
H. Programming and Central Station Reporting
The following parameters can be configured from the dealer website “Programming” Menu:
1. Automated and On Demand Test Signals (Default = Weekly)
The Automated Test signal interval can be changed from the dealer website to monthly,
weekly, daily, or hourly. In addition, an immediate test signal can be generated.
2. Activate/Deactivate Output Relay
Output relay #1 can be activated or deactivated from the dealer website.
This feature allows the installer to test the correct operation of this output
when it is connected to the alarm panel.
3. Normal State of Output Relay (Default = #1 Energized Open)
The normal state of the Output Relay can be changed from the dealer website.
4. Output Relay 1 Mapping
There are 6 trouble states that can be declared by the LTE30VZ, and each of
these states can be programmed from the dealer website to activate the
Output Relay.
The 6 trouble states are:
• Cellular Network Loss
• No Central Station Acknowledgement
• Low DC input Voltage
• Panel/LTE30VZ Cable Supervision Trouble
• Unit Disabled by Dealer Command
• Data Network Loss
• Total Failure
5. Send Trouble Condition to Central Station “Specific Event Reporting” (Default = Low DC
Input Voltage/DC Input Voltage Restoral, Input 1 Event/Input 1 Event Restoral, Panel
Armed/Panel Disarmed)
Any or all of the Trouble Conditions detectable the LTE30VZ can be programmed to
report that condition (and its Restoral) to the monitoring Central Station.
(INSTALLATION continued next page)