SIRCHIE ESP900 Technical Information Download Page 6

TI01-2ENG-REV13

6 of 8

NOTE: You will not receive an electrical shock by touching this knob, 

provided that your other hand is not touching any other surface. 

Touching the pickup mat or ground plane while the charge is being applied, 

however, could result in electrical shock. 

6. 

 While the pickup mat is charging, use the insulated roller to flatten out any 

air bubbles between the mat and the surface being examined (Fig. 2). 

7.   Normal charging time is approximately 15-30 seconds.  Longer charging 

produces better results, but will shorten battery life. The pickup mat being flat 

against the surface is a good indication that further charging is not necessary.

8.   Removing the unit from the surface will turn off the high voltage and auto-

matically reset the control knob to the High Voltage off position. 

9.   Lift the mat and examine the black surface for dust prints.

Lifting Dust Prints from Metal Surfaces

The ESP900 also lifts prints from metal surfaces such as desktops, vehicle 

bodies, metal cabinets, and other metal surfaces. Place the ground plane insu-

lating sheet within an inch of the pickup mat (Fig. 3). Center the ground plane 

on the insulating sheet leaving a 1/2" border around the ground plane. 

Failure to use the Ground Plane Insulator may result in arcing between the pickup mat and the metal 

surface of the pickup mat and may damage the surface being tested. 

1.  Switch the power ON and slowly increase voltage. On most metal surfaces, it will not be necessary to 

go beyond the lowest voltage setting.  Allow a charge for at least 15 seconds (30 seconds max). 

2.  After the charging cycle is complete, remove the unit.  

FIGURE 3

FIGURE 2

Summary of Contents for ESP900

Page 1: ...ke tire tracks and footprints is not the problem It s the not so obvious dust print impres sions that are difficult to locate accidentally damaged or obliterated The Electrostatic Dust Print Lifter is...

Page 2: ...vided ESP900 Contents 1 Electrostatic Voltage Control Unit 1 Ground Plane nickel plated steel 4 x 6 10 2cm x 15 2cm 1 Ground Plane Polycarbonate Insulating Sheet 5 x 7 12 7cm x 17 8cm 1 Insulated Roll...

Page 3: ...of LEDs RED High Voltage Ready will light when an electrical path has been established between the pickup mat and the ground plate GREEN Voltage LED s indicate the strength of the voltage output If no...

Page 4: ...r tab with the terminals making contact 4 With the battery in position replace the compartment cover The unit is ready for use Press the ON OFF switch The green button should illumi nate NOTE Energizi...

Page 5: ...tton The button should illuminate and the red LED below the voltage control knob will illuminate if the unit is properly position over the pickup mat and ground plate If the red LED does not come on m...

Page 6: ...ltage and auto matically reset the control knob to the High Voltage off position 9 Lift the mat and examine the black surface for dust prints Lifting Dust Prints from Metal Surfaces The ESP900 also li...

Page 7: ...print Lifter No 647C100 or Sirchie s GELifters CAUTION Attempts to add clear lacquer or similar materials to preserve the print on the lifting mat usually results in the destruction of lifted prints C...

Page 8: ...ifting mat didn t draw down completely to surface Check positioning of brass contacts between the mat and ground plane Increase voltage setting Brass contacts positioned incorrectly Check positioning...

Reviews: