SIRCHIE ESP900 Technical Information Download Page 5

TI01-2ENG-REV13

5 of 8

Operation

1.   Remove one of the pickup mats from its protec-

tive tube. Carefully place the mat, black side 

down, over the area to be examined.

2.   Position the Ground Plane 1-2 inches from one 

edge of the pickup mat as shown (Fig. 1A). 
NOTE: When working on vertical surfaces (Fig. 

1B), secure the pickup mat and ground plate in 

place with tape. 

3.   Place the electrostatic control unit on the ground 

plane and the pickup mat. The single brass elec-

trode (uppermost—top) must make contact with the metallized surface of the pickup mat and the 2 brass 

electrodes at the (lower) other end of the unit must contact the ground plane. 

4.   Press the ON/OFF button. The button should illuminate and the red LED below the voltage control knob 

will illuminate if the unit is properly position over the pickup mat and ground plate. If the red LED does 

not come on, make sure the brass electrodes are making good contact with the pickup mat and ground 

plate. 

5. 

 

To apply voltage, turn the control knob one position clockwise. This will apply approximately 4000 volts. 

On most surfaces, application of the electrical charge will cause the pickup mat to draw down to the 

surface. If not, advance the voltage control to a higher value. Each click of the knob will apply approxi-

mately 1000 additional volts. Rotating the knob clockwise after all the LEDs are lit will have no effect. 

If arching occurs between the pickup mat and the ground plate, lower the voltage by turning the control 

knob counter clockwise. 

FIGURE 1A

FIGURE 1B

Summary of Contents for ESP900

Page 1: ...ke tire tracks and footprints is not the problem It s the not so obvious dust print impres sions that are difficult to locate accidentally damaged or obliterated The Electrostatic Dust Print Lifter is...

Page 2: ...vided ESP900 Contents 1 Electrostatic Voltage Control Unit 1 Ground Plane nickel plated steel 4 x 6 10 2cm x 15 2cm 1 Ground Plane Polycarbonate Insulating Sheet 5 x 7 12 7cm x 17 8cm 1 Insulated Roll...

Page 3: ...of LEDs RED High Voltage Ready will light when an electrical path has been established between the pickup mat and the ground plate GREEN Voltage LED s indicate the strength of the voltage output If no...

Page 4: ...r tab with the terminals making contact 4 With the battery in position replace the compartment cover The unit is ready for use Press the ON OFF switch The green button should illumi nate NOTE Energizi...

Page 5: ...tton The button should illuminate and the red LED below the voltage control knob will illuminate if the unit is properly position over the pickup mat and ground plate If the red LED does not come on m...

Page 6: ...ltage and auto matically reset the control knob to the High Voltage off position 9 Lift the mat and examine the black surface for dust prints Lifting Dust Prints from Metal Surfaces The ESP900 also li...

Page 7: ...print Lifter No 647C100 or Sirchie s GELifters CAUTION Attempts to add clear lacquer or similar materials to preserve the print on the lifting mat usually results in the destruction of lifted prints C...

Page 8: ...ifting mat didn t draw down completely to surface Check positioning of brass contacts between the mat and ground plane Increase voltage setting Brass contacts positioned incorrectly Check positioning...