background image

 

 

5. Technical specifications 

 

ADS type > 

 

1200 TRX/ 

1210 TRA-TRB 

1240 TRX/ 

1250 TRA-TRB 

 

Optical 

  Wavelength(s) 

850/850-1310 

1310/1310-1550  nm 

  Fiber 

MM (2x/1x) 

SM (2x/1x) 

 

  Link budget 

20

1)

 / 20

1)

 at 

850 nm 

22 / 25 at 1310 

nm 

dB 

  Link length 

6 / 6 

55 / 55 

km 

  Output power 

>-15

1)

 / >-15

1)

 

>-7 / >-7 

dBm 

  Input sensitivity 

-35 / -35 

-32 / -32 

dBm 

 

Audio 

  Channels 

1 at port 1, 1 at port 2 (both full duplex) 

  Bandwidth 

40 to 15k 

Hz 

  Sampling rate 

16-bit 

 

  I/O level 

0 (+6 max) 

dBV 

  SNR 

>62  

dBA 

  THD 

<1 (at nom. level) 

  Input imped. 

<50 k



or

600 

 balanced  

  Output imped. 

<50 



balanced 

 

Contact closure 

 

Channels 

1 at port 1, 1 at port 2 (both full duplex) 

 

Activation at 

<0.75 (<1.5 k

 to ground) 

 

Input 

+5 V pull-up, 10 k

 

 

 

Output 

NO, fail-safe, potential-free 

 

 

Output switch 

1 A @ 30 Vdc 

 

 

Data (port 3; port 4) 

 

 

Channels per 
port 

RS-232; RS-485

 2)

 (2W, 4W), 

RS-422 or 20 mA digital CL) 

 

Data format 

Asynchronous, serial 

 

 

Interf. support  C. loop, TTY, TTL, Manch., Bi-ph. 

 

 

Data rate

4)

 

DC to 64 

kbit/s 

 

Sample rate

4)

 

512 ksamples/s 

 

 

Management 

 

 

 

Front panel 
LEDS 

see text 

 

 

SNM 
management 
variables 

Voltage, module temp., alarm 

status, configuration et al 

 

 

Environmental and Safety 

 

Operating temp. 

-40 to +74 

o

 

Humidity (max.) 

<95 (no condensation) 

 

Electrical safety 

AL / IEC / EN 60950-1 

 

 

UL recognition file 

E242498 

 

 

Laser safety 

IEC 60825-1, IEC 60825-2 

 

 

EMC immunity 
 

EN 55024, EN 50130-4,  

EN 61000-6-2 

 

 

EMC emission 

EN 55022 (Class B) 

FCC 47 CFR 15 (Class B) 

 

Powering 

 

Power cons. 

 

Power voltages 

11-15 (/SA) 

Vdc 

 

Mechanical 

 

 

Opt. connectors 

ST (MM)

 3)

, FC (SM) 

3)

 

 

 

Data, audio, 
CC connectors 

for RJ-45 plug (4x) 

 

 

Dimensions 

190x128x35 (7TE) 

mm 

 

Weight (appr.) 

450 

1)

 

For 

50/125

 

m fiber, subtract 4 dB 

2)

 Manchester/biphase compatible 

3)

 On one-fiber models, other connectors may be fitted on request 

4) 

Per channel 

 

Table 6. ADS 1200 series, technical specifications 

6. Safety, EMC, ESD 

 

General 

The  safety  information  contained  in  this  section,  and  on 
other pages of this manual, must be observed whenever this 
unit is operated, serviced, or repaired. Failure to comply with 
any  precaution,  warning,  or  instruction  noted  in  the  manual 
is  in  violation  of  the  standards  of  design,  manufacture,  and 
intended use of the unit. 
Installation,  adjustment,  maintenance  and  repair  of  this 
equipment are to be performed by trained personnel aware of 
the  hazards  involved.  For  correct  and  safe  use  of  the 
equipment  and  in  order  to  keep  the  equipment  in  a  safe 
condition,  it  is  essential  that  both  operating  and  servicing 
personnel follow standard safety procedures in addition to the 
safety precautions and warnings specified in this manual, and 
that  this  unit  be  installed  in  locations  accessible  to  trained 
service personnel only.

 

Siqura  assumes  no  liability  for  the  customer’s  failure  to 
comply with any of these safety requirements. 

 

UL/IEC/EN

 

60950-1: General safety requirements 

The  equipment  described  in  this  manual  has  been 
designed and tested according to the UL/IEC/EN 60950-1 
safety requirements. 

If there is any doubt regarding the safety of the equipment, do 
not  put  it  into  operation.

  This  might  be  the  case  when  the 

equipment  shows  physical  damage  or  is  stressed  beyond 
tolerable limits (e.g. during storage and transportation). 

Before  opening  the  equipment,  disconnect  it  from  all  power 
sources.

 The equipment must be powered by a SELV

*)

 power 

supply. 

 

When this unit is operated in extremely elevated temperature 
conditions, it is possible for internal and external metal 
surfaces to become extremely hot. 

 

Optical safety 
This optical equipment contains Class 1M lasers or LEDs 
and  has  been  designed  and  tested  to  meet  IEC  60825-
1:1993+A1+A2  and  IEC  60825-2:2004  safety  class  1M 
requirements. 

Optical  equipment  presents  potential  hazards  to  testing  and 
servicing personnel owing to high levels of optical radiation.

 

When  using  magnifying  optical  instruments,  avoid  looking 
directly into the output of an operating transmitter or into the 
end of a fiber connected to an operating transmitter, or there 
will be a risk  of permanent  eye  damage

.

  Precautions  should 

be  taken  to  prevent  exposure  to  optical  radiation  when  the 
unit  is  removed  from  its  enclosure  or  when  the  fiber  is 
disconnected from the unit. The optical radiation is invisible 
to the eye.

 

Use  of  controls  or  adjustments  or  procedures  other  than 
those  specified  herein  may  result  in  hazardous  radiation 
exposure. 

 

The  installer  is  responsible  for  ensuring  that  the  label 
depicted below (background: yellow; border and text: black) 
is present in the restricted locations where this equipment is 
installed. 

The  locations  of  all  optical  connections  are  listed  in  the 
Indications and Connectors section of this manual.

 

Optical  outputs  and  wavelengths  are  listed  in  the  Technical 
Specifications section of this manual. 

Hazard Level 1M

 

 

Reviews: