© 2003 - 2005 Sipura Technology, Inc
Proprietary (See Copyright Notice on Page 2)
55
Number of Cadence Sections = 1
Cadence Section 1: Section Length = 60s
Number of Segments = 4
Segment 1: On=0.2s, Off=0.2s
Segment 2: On=0.2s, Off=0.2s
Segment 3: On=0.2s, Off=0.2s
Segment 4: On=1.0s, Off=4.0s
Total Ring Length = 60s
•
FreqScript
– A mini-script that specifics the frequency and level parameters of a tone. Up to 127
characters. Syntax: F
1
@L
1
[,F
2
@
L2
[,F
3
@L
3
[,F
4
@L
4
[,F
5
@L
5
[,F
6
@L
6
]]]]], where F
1
–F
6
are frequency
in Hz (unsigned integers only) and L
1
–L
6
are corresponding levels in dBm (with up to 1 decimal
places). White spaces before and after the comma are allowed (but not recommended)
Example 1
: Call Waiting Tone
440@-10
Number of Frequencies = 1
Frequency 2 = 440 Hz at –10 dBm
Example 2
: Dial Tone
350@-19,440@-19
Number of Frequencies = 2
Frequency 1 = 350 Hz at –19 dBm
Frequency 2 = 440 Hz at –19 dBm
•
ToneScript
– A mini-script that specifies the frequency, level and cadence parameters of a call
progress tone. May contain up to 127 characters. Syntax: FreqScript;Z
1
[;Z
2
]. The section Zi is
similar to the S
i
section in a CadScript except that each on/off segment is followed by a frequency
components parameter: Z
i
= D
i
(on
i,1
/off
i,1
/f
i,1
[,on
i,2
/off
i,2
/f
i,2
[,on
i,3
/off
i,3
/f
i,3
[,on
i,4
/off
i,4
/f
i,4
[,on
i,5
/off
i,5
/f
i,5
[,on
i,6
/off
i,6
/f
i,6
]]]]]), where fi,j = n
1
[+n
2
]+n
3
[+n
4
[+n
5
[+n
6
]]]]] and 1 < n
k
< 6 indicates which of the
frequency components given in the FreqScript shall be used in that segment; if more than one
frequency component is used in a segment, the components are summed together.
Example 1
: Dial Tone
350@-19,440@-19;10(*/0/1+2)
Number of Frequencies = 2
Frequency 1 = 350 Hz at –19 dBm
Frequency 2 = 440 Hz at –19 dBm
Number of Cadence Sections = 1
Cadence Section 1: Section Length = 10 s
Number of Segments = 1
Segment 1: On=forever, with Frequencies 1 and 2
Total Tone Length = 10s