  SAFETY INSTRUCTIONS….cont 

CAUTION: 

The  warnings  and  cautions  mentioned  in  this  user  manual  can  not  cover  all  possible 

conditions  and  situations  that  may  occur.  It  must  be  understood  by  the  operator  that  common 

sense and caution are factors which cannot be built into this product, but must be applied. 

When installing, please ensure your SIP submersible pump is disconnected from 

the electrical supply to prevent possible injury to people and / or damage due 

to un-wanted start up. 
Avoid inserting hands or other objects into the inlet / outlet of the pump whilst it is 

connected to the mains supply. 
Use the handle provided to transport or lift the pump. 
Always check the pump regularly, and take it out of service if the water is likely 

to freeze. 
When not in use, always ensure that the pump is fully drained of any water and 

stored in a warm environment to protect it from frost damage. 
Never allow the pump to run without water flowing through it. 
The pump should not be used where aquatic life is present such as in a domes-

tic, or commercial pond, or similar. 
Always rinse the pump with clean water and fully drain after each use. 
Never  carry  the  water  pump  by  the  mains  lead  or  pull  it  to  remove  the  plug 

from the mains socket, or the pump from the water. 
Keep the mains lead away from heat, oil and sharp edges. 
If the mains lead is damaged, it must be replaced by the manufacturer or its 

service agent or a similarly qualified person in order to avoid unwanted hazards. 
Never use flammable or corrosive liquids to clean the water pump. 
Never use the water pump to pump anything other than water, it should not be 

used to pump flammable, corrosive or other potentially damaging or danger-

ous liquids. 
The ambient temperature should be no less than 0°C. 
We  recommend  that  the  pump  should  be  switched  on  every  3  months  for  a 

few minutes. 

 

 

 

If the water pump is used in a place of work all rules and laws etc. relating to the use 

of portable electrical appliances should be followed. 

19 

  PARTS LIST  

Ref No. 

Description 

SIP Code 

Ref No. 

Description 

SIP Code 

1. 

Mains lead 

PW11-00085 

21. 

Adjusting washer 

PW11-00095 

2. 

Float switch 

PW11-00086 

22. 

Impeller 

PW11-00096 

3. 

Top cover 

PW11-00087 

23. 

Nut M8 

PW11-00071 

4. 

Cable protection 

PW11-00053 

24. 

Casing 

PW11-00097 

5. 

Cable gland 

PW11-00054 

25. 

Steel ball 

PW11-00073 

6. 

Capacitor 

PW11-00088 

26. 

Gasket 

PW11-00098 

7. 

Capacitor gland 

PW11-00056 

27. 

Screw 2.9x8  

PW11-00099 

8. 

Screw 3.9x30 

PW11-00057 

28. 

Screw 4.2x32  

PW11-00074 

9. 

Insulation plate 

PW11-00058 

29. 

O-ring 

PW11-00126 

10. 

Metal cover 

PW11-00089 

30. 

Base 

PW11-00100 

11. 

Wave washer  

PW11-00060 

31. 

Screw 4.2x18 

PW11-00077 

12. 

Bearing 6201 

PW11-00061 

32. 

Bottom cover 

PW11-00101 

13. 

Rotor 

PW11-00090 

33. 

Screw 4.2x18 

PW11-00077 

14. 

Bearing 6201 

PW11-00061 

34. 

Elbow 

PW11-00078 

15. 

Stator 

PW11-00091 

35. 

Elbow o-ring 

PW11-00079 

16. 

Motor lining 

PW11-00092 

36. 

Hose adaptor 

PW11-00080 

17. 

Motor front cover 

PW11-00093 

37. 

Screw M4x6 

PW11-00081 

18. 

Oil Seal 24x11x4.5 

PW11-00066 

38. 

Spring washer M4 

PW11-00082 

19. 

Mechanical seal 

PW11-00094 

39. 

Earth wire 

PW11-00083 

20. 

Main seal 89.5x5.2 

PW11-00068 

40. 

Lock washer M4 

PW11-00084 

   06881 SUB1015FS 

Summary of Contents for SUB1010FS, SUB1015FS

Page 1: ...ckaging to the local amenity tip and place into the appropriate recycling bin Never dispose of electrical equipment or batteries in with your domestic waste If your supplier offers a disposal facility...

Page 2: ...FS Water pump SIP Part No 06881 Sub 1025SS Water pump SIP Part No 06885 Conforms to the requirements of the following directive s as indicated 2006 95 EC Low Voltage Directive 2004 108 EC EMC Directiv...

Page 3: ...al Specifications 10 Contents Accessories 11 Getting to Know Your Water pump 12 Operating Instructions 14 Maintenance Instructions 15 Troubleshooting 16 Exploded Drawing 06879 Sub 1010FS 17 Parts List...

Page 4: ...SAFETY INSTRUCTIONS IMPORTANT Please read the following instructions carefully failure to do so could lead to serious personal injury and or damage to the water pump 21 Ref No Description SIP Code Ref...

Page 5: ...check for any damage and determine that it will operate correctly and perform its intended func tion Check for alignment of moving parts free running of moving parts breakage of parts and any other co...

Page 6: ...wanted hazards Never use flammable or corrosive liquids to clean the water pump Never use the water pump to pump anything other than water it should not be used to pump flammable corrosive or other po...

Page 7: ...lica tions Draining of cisterns rainwater reservoirs wells ponds swimming pools storm drains flooded cellars boats and yachts They are only for use with water and not chemicals or other substances tha...

Page 8: ...markings in your plug pro ceed as follows The wire which is coloured blue must be connected to the terminal marked with N or coloured black The wire which is coloured brown must be connect ed to the t...

Page 9: ...butor as soon as possible Note Proof of purchase will be required before any warranty can be hon oured GUARANTEE ELECTRICAL CONNECTION cont Warning Never connect live or neutral wires to the earth ter...

Page 10: ...urrent circuit breaker tripped 3 Power supply problem 4 Float switch problem 5 Impeller jammed 1 Check and replace with correct rated fuse 2 Check and reset 3 Check with a qualified elec trician 4 Man...

Page 11: ...ter to remove debris Re fit the base and o ring and secure with the retaining screws 1 2 3 1 2 3 06879 06881 06885 Screws Clean and store the pump in a dry and frost free place after each use the am b...

Page 12: ...e water pump Push your hose onto the hose adaptor see page 12 Secure using a relevant pipe clip or similar pipe clip not supplied Lower the pump into the water use rope or similar around the handle to...