background image

12 

 

4.

 

Usage of an inappropriate extension cable (too long, small diameter of wires) can cause 
insufficient power of the device - see the safety regulations.  

5.

 

In case of other problems contact your supplier. 

9

 

Storage and maintenance 

 

9.1

 

Cooling, dismantling and storage 

After completion of heating, make sure that the coil holder and coils used are placed in a safe place. 
Handling the device or its parts before letting it cool down can result in injury, damage to the 
equipment or fire. 

 

After completion of heating, leave the device turned on for 10 more minutes – the device will be 
cooled down by fans until cooled off completely and then will turn off the fans. Then shut it down by 
the main power switch and disconnect it from the power supply. 

If you unplug the unit immediately, let all working coils cool down for at least 15 minutes.  

After cooling, place the device and its accessories in the case. Place the cords so as to avoid their 
sharp bending or twisting – it could cause their damage. 

9.2

 

Proper cleaning and maintenance 

Make sure the device is turned off, unplugged and cooled. Use a dry, clean cloth or paper towel to 
remove grease, oil and other impurities from the machine, applicators and cables before placing 
06434 in the storage case. 

 

Use freely available non-volatile cleaning agents for grease, oil and dirt that is difficult to remove. 
Before the first reuse of 06434 allow all components to air dry. 

Do not immerse any part of the device in water or other liquids. Do not spray and wash the device 
down with water spray. Do not clean the components with volatile organic compounds such as 
gasoline, benzene, kerosene, methyl ethyl ketone (MEK), fuel oil, brake parts cleaners, paint and 
thinner remover, varnish removers, self-adhesive solvents, etc. These substances cause fire and 
cause hardening or dissolving of polymeric materials used in the device. 

Do not use heat sources, heaters, burners, microwave ovens or gas furnaces, etc. for drying the 
device and its parts after cleaning. 

10

 

Warranty 

1.

 

Machine warranty period is determined by the manufacturer for 12 months from the sale of 
machinery buyer. Warranty period begins on the date of delivery of the machine to the 
purchaser, or the possible delivery date. The warranty period does not cover expendable 
parts – coils. Warranty period does not include the period from the application of a 
legitimate complaint until the machine is repaired. 

Summary of Contents for 06434

Page 1: ...Heat Induction Tool 06434 Instructions for use and Maintenance...

Page 2: ...Flat coil 9 6 3 Customized fixed coil 10 6 4 Flexible coil 10 6 5 Focus coil 11 7 DEVICE INDICATORS 11 8 POSSIBLE PROBLEMS AND TROUBLESHOOTING 11 9 STORAGE AND MAINTENANCE 12 9 1 Cooling dismantling a...

Page 3: ...ight 4 5kg 9 921lb Dimensions 200 x 140 x 75mm 4 Safety instructions 4 1 General safety rules Read carefully all instructions in the manual Failure to follow these instructions may result in electric...

Page 4: ...igh temperatures generated by the use of 06434 may cause serious burns in the case of touching the heated part Always keep proper footing and balance for safe control of the 06434 even in unexpected s...

Page 5: ...gas tanks it may pose a danger of explosion or fire Using coils with damaged insulation will void the warranty 4 5 Safety rules for using the device Do not leave 06434 uncontrolled when it is started...

Page 6: ...se a generator with a power output of at least 3 4 kW or DC AC inverter with a power output of 2 3 kW and only with a sine wave do not use the inverter with a square or quasi sine wave Failure to comp...

Page 7: ...s activated during the pressing of the button do not exceed the operating cycle of 2 minutes of heating and 2 minutes of cooling 5 After finishing the cycle release the button on the handle and remove...

Page 8: ...g rust paint oil etc from the heated material During heating there should be a gap around 3 5mm between the coil and the heated material to avoid excessive wear of the heating coil Holding of the coil...

Page 9: ...ial steel sheet metal 1 Connect the coil to the coil handle 2 Place the coil with its area over the material 3 Press the button and guide the coil above the material in a gyratory movement 4 After hea...

Page 10: ...etc and in applications where is not possible to use attachable coils Applications 1 Connect one end of the coil to the coil holder and secure it by the locking screw 2 Wrap the free end of the condu...

Page 11: ...Heating in progress Yellow flashing Device is overheated Red flashing Bad coil or power overload Red light Error 8 Possible problems and troubleshooting 1 06434 is designed and constructed so that wh...

Page 12: ...cloth or paper towel to remove grease oil and other impurities from the machine applicators and cables before placing 06434 in the storage case Use freely available non volatile cleaning agents for g...

Page 13: ...be exclusively used by original equipment manufacturer 6 During the warranty period are not allowed any modifications or changes to the machine which can affect the function of each part of the machi...

Page 14: ...220mm M8 00523 DHI IND423 Induction coil straight 23 220mm M10 00524 DHI IND426 Induction coil straight 26 220mm M12 00525 DHI IND432 Induction coil straight 32 220mm M16 00526 DHI IND438 Induction co...

Page 15: ...able spare parts No Name Part Ref 1 Coil DHI coil 2 Clamping bolts DHI bolts 3 Holder of induction coil handle DHI handle 4 Cable DHI cable 5 Strap DHI strap 6 Side cover DHI side cover 14 Electrotech...

Page 16: ...of explosion Risk of fire Caution intense magnetic field Caution source of intensive heat Read the operation manual before starting the equipment Use protective equipment goggles Use protective equip...

Page 17: ...y generator or by DC AC invertor where there is not a sine wave at the output there is only square wave or quasi sine wave or the power output is not sufficient Connect the equipment to another socket...

Page 18: ...of Conformity Producer SERENCO UK Ltd NN6 0BN Declare that the product Induction heater 06434 Is determined for the industrial use 17 2003 Sb LVD a 616 2006 Sb EMC Verified by the compliance with the...

Page 19: ...19...

Page 20: ...20...

Page 21: ...21...

Reviews: