background image

Sinterit INTERTEK Vacuum Cleaner USER MANUAL   |  17

IMPORTANT!

Only the flawless condition of all components guarantees the grounding and safety using the 
vacuum cleaner! 

4.  Put the Main Star filter back in place.
5.  Connect the internal grounding!
6.  Fit the Motor Head to the Filtering Chamber. 

CAUTION!

• 

Danger of crushing upper limbs when fitting and locking the Motor Head on the Filtering 
Chamber. 

• 

Never place hands between the Filtering chamber and Motor Head while locking.

• 

Do not put hands on the sides of the container near the guide pins while locking.

• 

Perform the container locking operation by means of the levers located on the side, USING 
BOTH HANDS!

Now you have two options: 

•  you can use INTERTEK Vacuum Cleaner to remove the powder from the printing chamber 

(using connected Sinterit Powder Separator to collect the unsintered powder);

•  vacuum dust around the work area using a floor brush connected straight to the hose.

DUST

OR

DUST

POWDER

Image 10. Two ways of using the Sinterit INTERTEK Vacuum Cleaner.

IMPORTANT!

For full instructions on how to use the Sinterit Powder Separator with the Sinterit INTERTEK 
Vacuum Cleaner, please refer to Sinterit Powder Separator’s user manual. 

Summary of Contents for ATEX Vacuum Cleaner

Page 1: ...efers to product Atex Vacuum Cleaner NRTL certified ETL Intertek listed Read the instruction manual before using the device Internal device construction differences might appear betweet products with...

Page 2: ...e these instructions The machine is supplied with User manual Test Sheet Warranty Slip Approval Certificate This manual provides all the information needed to use and service your Sinterit INTERTEK Va...

Page 3: ...ng repair and maintenance 13 G Toxic and dangerous materials 13 H Safety plates specification tag and symbols 14 I Scrapping 15 6 Initial startup of the Sinterit INTERTEK Vacuum Cleanerr after deliver...

Page 4: ...regulations and intervention procedures indicated in this manual The safety warnings and warning notices are indicated in this manual and on the product Unless these hazard messages are heeded the op...

Page 5: ...instructions before taking action 2 Contents of the Sinterit INTERTEK Vacuum Cleaner pack The Sinterit INTERTEK Vacuum Cleaner a package for the additional equipment Sinterit INTERTEK Vacuum Cleaner U...

Page 6: ...m external wire with grounding clamp Image 3 Back view of the Sinterit INTERTEK Vacuum Cleaner 8 Power cable 9 Suction hose connector 10 Filtering chamber s handles 11 Power cable hanger 14 15 13 12 I...

Page 7: ...aner available in options 110 i 230 V with ATEX Z22 certification 110 V with Intertek certification Waiting time depends on the selected option GENERAL Category Vacuum cleaner Type Industrial PACKAGIN...

Page 8: ...he phonometric test results on this specific model correspond to the following acoustic pressure at 1 meter distance from the vacuum and at 1 60 meter height where there is the noisiest part of the va...

Page 9: ...o wear or damage Applied directives The following directives apply to the vacuum cleaner described in this manual Ordinary Locations UL 1017 CSA C22 2 N 243 10 Hazardous Locations ISA 12 12 01 2016 CS...

Page 10: ...LOSION HAZARD Do not disconnect while the circuit is live or unless the area is free of ignitible concentrations Do not connect or disconnect when energized ATTENTION Risk of crushing upper limbs whil...

Page 11: ...these Periodically check the mains power cable to ensure it is not damaged In the event of the cable plugs or couplings being replaced make sure these are protected against water spray and check mech...

Page 12: ...ied atmosphere area after having disconnected and unplugged the machine and only after 10 minutes from unplugging Non classified atmosphere which means in an area with non potentially explosive atmosp...

Page 13: ...r and therefore cancel this certification Any alterations to the appliance can only be made by Sinterit Support WARNING NON SPARKING DEFLECTOR The vacuum cleaner is provided with a brassy non sparking...

Page 14: ...to CSA Std C22 2 68 C22 2 243 C22 2 213 MOD Sinterit INTERTEK Vacuum Cleaner ELECT RATING S N 104 127V 60 Hz 14A 1 1KW 1PH 200218356 MARKING CLASSII DIVISION 2 GROUPS F G AMBIENT TEMP RANGE 0 C T 40...

Page 15: ...enough to fully protect against all the hazards that could arise during vacuum cleaner operation These will have to be integrated with common sense and the experience of the operator both of which ar...

Page 16: ...nd injury 1 Set on the castors brake 6 to ensure that the machine is stable 2 Check that the nut of the grounding system 7 on the vacuum cleaner is tightly screwed in 3 Check the components inside the...

Page 17: ...the sides of the container near the guide pins while locking Perform the container locking operation by means of the levers located on the side USING BOTH HANDS Now you have two options you can use IN...

Page 18: ...ner safety plate 4 Ensure that the Power cable 8 and the optional extension are in perfect conditions 5 Connect the vacuum cleaner grounding system 7 to a conductive surface 6 Plug the Power cable int...

Page 19: ...let nozzle by hand Image 11 Incorrect and correct removing the powder from the print chamber 3 The capacity of the collected material in each device should not exceed 3 4 of the container After each c...

Page 20: ...ot to damage the Power cable 7 Disconnect the internal grounding 16 from the connector 21 to get to the Main Star filter Image 14 5 21 16 Image 13 Release the Release fasteners Image 14 Disconnect the...

Page 21: ...ical maintenance The Safety Manager has the precise duty of determining the professional capacities and skills of such persons Before doing any maintenance job the safety manager must Make sure there...

Page 22: ...faults or defects Screws and nuts must always be tightened Clean the Non sparkling deflector 19 inside on a regular basis to prevent dust accumulation inside the Filtering chamber Remove the Motor Hea...

Page 23: ...et to the Main Star filter Image 16 5 21 16 Image 15 Release the Release fasteners Image 16 Disconnect the internal grounding 16 with connector 21 7 Remove the Main Star filter Watch out for the powde...

Page 24: ...POSSIBLE FAULT RECOMMENDED REMEDY The vacuum cleaner fails to start No power 1 Check the power mains supply 2 Check the integrity of the plug and Power cable Dust leaking out Perforated Antistatic ho...

Page 25: ...nly with the product called Sinterit INTERTEK Vacuum Cleaner Due to the constant development of Sinterit s products the information contained in this manual specifications and markings are subject to...

Page 26: ...malfunction caused by dismantling alterations tuning or other changes of the product by a client or any third party made without written consent of Sinterit damages abnormalities or malfunction cause...

Page 27: ...e liquid produced vapours or combustible liquid produced vapours are not likely to exist under normal operating conditions Groups F G Material Properties F Carbonaceous Dusts G Non Conductive Dusts fl...

Page 28: ...SINTERIT Sp z o o ul Nad Drwina 10 bud B3 30 741 Krakow Poland www sinterit com Contact 48 570 967 854...

Reviews: