IDD-213C User Manual
18
Plug indication
Unplug notification
Emergency
Default thresholds for alarms:
High RPM: 4500r/min
Speeding: 120km/h
Low battery voltage: 10.5V
High engine coolant temperature: 98℃
Hard acceleration: 0.4g
Hard brake: 0.6g
Excessive engine idle time: 15min
Fatigue driving: 240min
5.14
Working Mode
Device supports 3 types of working mode: Passenger car, Heavy duty and Tracker
mode.
With tracker mode, device does not report diagnostic data, DTCs, trip fuel
consumption and some alarms including high RPM, high engine coolant temperature,
hard acceleration, hard brake, excessive engine idle time, MIL and excessive exhaust
emission.
With Tracker mode, device wakes up from sleep on detecting motion state last for 20
seconds, and goes into sleep on detecting static state last for 3 minutes.
5.15
GPS/Cellular Timer
GPS and cellular can keep working after ignition off according to configured timer, but
no regular reports during this period. This function is disabled by default. (
Supported
from firmware V2.1.2
)
The timer for GPS/Cellular can be 5-7200min and default setting is 720min, for data
connection can be 5-120min and default setting is 60min.
5.16
SMS Alert
If user mobile phone numbers are configured, device sends SMS to each user number
when alarms are triggered or eliminated, it is disabled by default.