Problem
Cause
Solution
No overload warning
The load has not been
calibrated or the height is
incorrect
•
The sensor has not been calibrated.
•
The wiring of the load sensor is incorrect.
•
The sensor is not in good condition.
The machine moves
and then stops
intermittently
The battery level is low/the
calibration is incorrect
•
Re-calibrate the parameters.
•
The battery is out of power. The electricity meter
only can be referred.
After setting, the
parameters could not
be saved successfully
after several trials.
The storage is abnormal
•
The parameters cross the line.
•
The lower platform controller is malfunctioning.