INSTALLATION
4
Installation
After uncrating your slicer, inspect the machine for any damage that might
have occurred during shipment. Report any damage to us before
proceeding to operate or service this machine. Never attempt to operate
the machine with damaged parts.
Select a location for your slicer with sufficient room for operating, cleaning
and servicing, and the floor must be solid and level. After locating the
machine, skid the four castors to fix the machine.
Remove the rear cover to get access to the 2 rear screws. At the front, open
door and remove the crumb basket.
The loading ramp has been stored for shipping against the front top part of
the machine. Rotate the ramp and fix the link with the frame at the rear. Put
the safety guard cover in place. Mount the bread guides on the ramp. Be
ready to lift the blower table.
Remove all the packing meterial. Remove the extra blades shipped in the
crumb basket and keep them in a safe place.
Electric Connection
Connect the electric cables to the machine with a circuit breaker which is
about 1.5m high over the ground.
Connect the right power supply according to the indication on the machine
nameplate.
The machine must be in ground protection.