20. Alignment of needle plate to hook
Checking
1. After adjusting needle clearance to shuttle, attach needle plate. At this time, make sure to check the
needle is correctly positioned to the needle hole as shown below.
Adjustment:
1. Remove needle plate
2. Loosen the two hexagonal screws (A)
3. Adjust the needle plate position, with the two plate stopper plates (B) located at either side of feed dog
,so that to needle is in its centre position of the needle hole in the needle plate, when looking from the
side of the machine
4. Tighten the the two screws (A) on the stopper plate securely.
A
B
A