11. Adjustment of needle at center position
Check
1. Set the machine on straight stitching, center position.
2. Insert a new # 90 needle.
3. The needle position should now be in the centre of the middle slots of needle plate, see illustation 1.
Adjustment
1. Remove face cover.
2. Break loose the 2mm hex set screw (A).
3. Turn eccentric screw (B) on needle bar until the needle is in the centre of the middle slots of needle
plate, see illustation 1
4. Tighten the 2 mm hex set screw (A).