User Manual of A90 Series Inverter
248
F18.41
~
F18.50
Reserved
F18.51 PID output
-300.0 to 300.0
%
F18.51 PID output
-100.0 - 100.0
%
F18.60
Inverter
temperature
-40 to 200
°C
F18.67
Cumulative
energy saving
MWH
0 - 65535
MW
h
F18.68
Cumulative
energy saving
KWH
0.0 - 999.9
kW
h
F18.69
High cumulative
cost saving
(*1000)
0 - 65535
F18.70
Low cumulative
cost saving
0.0 - 999.9
F18.71
Power-frequency
power
consumption
MWH
0 - 65535
MW
h
F18.72
Power-frequency
power
consumption
KWH
0.0 - 999.9
kW
h
7.19
Fault Record Parameter Group of F19 Group
This group of parameters is used only to view the types of last three faults of the
inverter and the inverter status at the time of failure. They cannot be changed.
The function codes related to the last fault are as follows.
Function
code
Function code
name
Parameter description
Unit
Default
setting
Attribute
F19.00 Last fault category
Display the type of the last fault,
as detailed in Table 7-22 List of
Fault Types.
0
×
F19.01
Output frequency
in failure
Display the output frequency in
the last fault.
Hz
0.00
×
F19.02
Output current in
failure
Display the output current in the
last fault.
A
0.00/0.0
×
F19.03
Bus voltage in
failure
Display the bus voltage in the
last fault.
V
0
×
F19.04
Running status in
failure
Display the running status in the
last fault, as detailed in Table
0
×