Sinclair SYMPHONY MS-H09AISW PT User Manual Download Page 8

5

Introduction for buttons on remote controller

LCD displays“     ”. Press the button for the second time to start healthy and scavenging

functions simultaneously; LCD displays“     ” and “     ” . Press this button for the third

time to quit healthy and scavenging functions simultaneously. Press the button for the

fourth time to start healthy function; LCD display “      ”. Press this button again to repeat

the operation above.

/

SLEEP:

Press this button, can select Sleep 1 (            ), Sleep 2 (           ),Sleep 3 (           ) and cancel
the Sleep,circulate between these, after electrified, Sleep Cancel is defaulted.

Sleep 3- the sleep curve setting under Sleep mode by DIY:

(1) Under Sleep 3 mode, press "Turbo" button for a long time, remote control enters into user 

individuation sleep setting status, at this time, the time of remote control will display "1hour ", 

(2) Adjust "+" and "-" button, could change the corresponding setting temperature, after 

adjusted, press "Trubo "button for confirmation;

(3) At this time, 1hour will be automatically increased at the timer postion on the remote 

(4) Repeat the above step (2)

(3) operation, until 8hours temperature setting finished,

sleep,curve setting finished, at this time, the remote control will resume the original timer

the setting temperature "88" will display the corresponding temperature of last setting sleep

curve and blink (The first entering will display according to the initial curve setting value of 

original factory);

control, (that are "2hours " or "3hours " or "8hours "), the place of setting temperature "88" 
will display the corresponding temperature of last setting sleep curve and blink;

display;temperature display will resume to original setting temperature.

Sleep3- the sleep curve setting under Sleep mode by DIY could be inquired:

The user could accord to sleep curve setting  method to inquire the presetting sleep curve, 

enter into user individuation sleep setting status, but do not change the temperature, press 

"Turbo" button directly for confirmation.Note: In the above presetting or enquiry procedure,

if continuously within10s, there is no button pressed, the sleep curve setting within

10s, there is no button pressed, the sleep curve setting status will be automatically

quit and resume to display the original displaying. In the presetting or enquiry procedure, press

Sleep 2 is sleep mode 2, that is air conditioner will run according to the presetting a group of
sleep temperature curve.

"ON/OFF" button, "Mode" button, "Timer"button or "Sleep" button, the sleep curve setting 

or enquiry status will quit similarly.

:

Sleep 1 is Sleep mode 1, in Cool mode: after run for one hour in sleep mode, the

main unit setting temperature will increase 1

, after 2 hours, the setting temperature will

increase 2

, but the maximal setting temperature is 30

, then the unit will run at this 

setting temperature all along; In Heat mode: after run for one hour in sleep mode, the 

setting temperature will decrease 1 

after 2 hours the setting temperature will 

decrease 2

, but the minimal setting temperature is 16

, then the unit will run at this 

setting temperature all along. 

7

8

Press this button to achieve the on and off of healthy and scavenging functions in 

operation 

status.Press this button for the first time to start scavenging function;

Air function is applicable for some models. 

Summary of Contents for SYMPHONY MS-H09AISW PT

Page 1: ...USER S MANUAL MS H09AISW MS H12AISW MULTI SYSTEM SYMPHONY...

Page 2: ...Original instructions...

Page 3: ...tainable reuse of mate rial resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for env...

Page 4: ...Please contact dealer when you need to repair air conditioner Do not block air inlet It may cause malfunction person can perform the work Otherwise it may cause personal injury or damage injury or da...

Page 5: ...tual products Display content or position may be different from above graphics please refer to actual products Indoor Unit remote controller air inlet panel horizontal louver air outlet heating indica...

Page 6: ...on Set temperature Set time X FAN function TIMER ON TIMER OFF Child lock Up down swing Left right swing Set fan speed Light Temp display type Set temp Outdoor ambient temp Indoor ambient temp Sleep mo...

Page 7: ...peration mode in accordance with the room temperature to make indoor room comfortable As for cooling only unit it won t have any action when it receives the signal of heating operation This button is...

Page 8: ...last setting sleep curve and blink display temperature display will resume to original setting temperature Sleep3 the sleep curve setting under Sleep mode by DIY could be inquired The user could acco...

Page 9: ...tting press TIMER ON button to confirm will be constantly displayed Press T OFF button to initiate the auto off timer To cancel the auto timer program simply press the button again TIMER OFF setting i...

Page 10: ...three times At unit OFF press MODE and buttons simultaneously to switch between and Combination of and buttons About lock About Back lighting Function Combination of MODE and buttons About switch bet...

Page 11: ...an and Maintenance Note Turn off the air conditioner and disconnect the power before cleaning the air conditioner to avoid electric shock Do not wash the air conditioner with water to avoid electric s...

Page 12: ...Open panel Pull out the panel to a certain Use dust catcher or water to the water below 45 to clean it and then put it in a shady and cool place to dry panel cover tightly Note operation environment c...

Page 13: ...roded If yes please contact dealer 5 Check whether drainage pipe is damaged 1 Disconnect power supply 2 Clean filter and indoor unit s panel 3 Check whether mounting bracket for outdoor unit is damage...

Page 14: ...oom Pull out the plug Reinsert the plug after about 3min and then turn on the unit again Signal receiving range is 8m Remove obstacles Select proper angle and point the remote controller at the re cei...

Page 15: ...r temperature and hum idity is high Because indoor air is cooled rapidly After a while indoor temperature and humidity will be decrease and mist will disappear Phenomenon Check items Solution Set temp...

Page 16: ...n the unit again Outdoor unit has vapor Heating mode is turned on During defrosting under he ating mode it may generate vapor which is a normal phenomenon Water noise Air conditioner is turned on or t...

Page 17: ...ation of error code Above indicator diagram is only for reference Please refer to actual product for the actual indicator and position When below phenomenon occurs please turn off air conditioner and...

Page 18: ...15 Installation dimension diagram At least 250cm At least 15cm At least 300cm Space to the ceiling Space to the obstruction At least 15cm At least 15cm Space to the wall Space to the wall...

Page 19: ...be installed 2 5m 7 Don t install the indoor unit right above the electric appliance Indoor unit 1 The place with strong heat sources 8 Please try your best to keep way from fluorescent lamp or volat...

Page 20: ...e keep the interconnec tion cable away from the copper tube 9 The appliance shall be installed in accordance with national wiring regulations grounding with specialized grounding device by a professio...

Page 21: ...le should be a little lower than the wall mounted frame shown as below Step three open piping hole 2 Open a piping hole with the diameter of 55 on the selected outlet pipe position In order to drain s...

Page 22: ...ing out the pipe from left or right please cut off the corresponding hole on the bottom case cut off the hole left right 1 The pipe can be led out in the direction of right rear right left or rear lef...

Page 23: ...screw on the wiring cover and then take Step seven connect wire of indoor unit 4 Wrap the indoor pipe and joint of con then wrap it with tape Step six install drain hose Installation of indoor unit to...

Page 24: ...parting and the contact parting distance should be more than 3mm 3 Remove the wire clip connect the power connection wire to the wiring terminal according to the color tighten the screw with wire clip...

Page 25: ...parately at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom drain hose band connection pipe indoor power cord Step nine hang the i...

Page 26: ...unit grounded securely It may cause electric leakage Does the power cord follow the speci fication It may cause malfunction or damaging the parts Is there any obstruction in the air inlet and outlet I...

Page 27: ...length of liquid pipe The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet Additional refrigerant charging amount prolong...

Page 28: ...r of connection pipe Liquid pipe mm Gas pipe mm 6 6 or 9 52 9 52 or 12 12 16 19 22 2 16 or 19 19 or 22 2 25 4 or 31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350 120 120 5...

Page 29: ......

Page 30: ...ble natural resources and help in preventing potential negative impacts to environment and human health which could be consequence of incorrect disposal of waste Ask for more details from local author...

Reviews: