![Sinclair SWH-190-300IRE Installation And Operating Manual Download Page 53](http://html1.mh-extra.com/html/sinclair/swh-190-300ire/swh-190-300ire_installation-and-operating-manual_1280331053.webp)
53
12 - TECHNICAL DATA
Size
190
300
Ventilation
Type of fan
Centrifugal
Air flow
m
3
/h 270
414
Available pressure head
Pa 25
25
1. Inlet water temperature 15 °C, accumulator set 45°C, air on source side 15°C D.B /12°C W.B.
2. The product complies with the European Directive ErP, which includes the Commission Delegated Regulation (EU) N. 812/2013 and the Commission Delegated Regulation N.
814/2013, Average Climate, Heat Pump Water Heater
3. The product complies with the European Directive ErP, which includes the Commission Delegated Regulation (EU) N. 812/2013 and the Commission Delegated Regulation N.
814/2013, Warmer Climate, Heat Pump Water Heater
4. The product complies with the European Directive ErP, which includes the Commission Delegated Regulation (EU) N. 812/2013 and the Commission Delegated Regulation N.
814/2013, Colder Climate, Heat Pump Water Heater
5. Data referred to completely ducted unit.
6. Maximum temperature that can be reached during Anti-legionella mode(Dinsifect)
*It contains fluorinated greenhouse gases
OPERATING LIMITS
Size
190
300
Power supply (1)
V
220-240/1/50 220-240/1/50
F.L.A. - Current absorbed at the maximum allowed conditions
A
9,10 9,80
F.L.I. - Power absorbed at full load (at the maximum allowed conditions)
kW
2,10 2,25
M.I.C - Maximum inrush current
A
22,2 33,7
ELECTRICAL DATA
1) Power supply 220-240/1/50 Hz
For power voltages other than the standard, contact the technical department
The units are conforming with the prescriptions of European Standards CEI EN 60204 and CEI EN 60335
Warning: when defining the correct size, verify that all absorption is compliant with current electrical supply
contracts in force in the country of installation
300
1. Use range of the heat pump
2. Use range of the electrical heating element
3. Use range of the electrical heating element only in Anti-Legionella mode
(Disinfect)
Twu [°C] water temperature in the accumulator
Tae [°C] air temperature at exchanger inlet
190
Summary of Contents for SWH-190-300IRE
Page 54: ...54...
Page 55: ...55...
Page 56: ...56...
Page 57: ...57 NOTE...
Page 58: ...58 NOTE...