Installation & Owner‘s Manual

VACATION

CANCEL

CLOCK
TIMER

DISINFECT

ON/OFF

 3.1

 3.2

 3.2

500

1000

1500

2000

2500

3000

-7 -5

2

7

15 20 25 30 32 35 40 45

Ambient temp(

ć

)

Capacity(W)

15-45
15-55
15-65
15-70

ķ

Ĺ

ĺ

Ļ

ļ

Ľ

ľ

Ŀ

ĸ

 

 

 

 

E-heater will be activated once for the current heating progress, 
if want to apply E-heater again, plsease push              .

Modes will be automatically selected by unit. manually mode 
selection is unavailable.

Running Temperature Range
Setting water temperature target range: 38~70ºC.
E-heater running ambient temperature range: -20~45ºC.
Heat pump running ambient temperature range: -7~43ºC.
Water temperature limits:

Defrosting During Water-heating 
In heat pump running period, if the evaporator frosted in lower 
ambient temperature, the system will defrost automatically to 
keep effective performance(about 3~10min). At defrosting time, 
the fan motor will stop, but compressor will still run.

Heat-up Time 
There are different heat-up times in different ambient tempera-
ture. Normally lower ambient temperature result longer heat-up 
time because of lower effective performance.

Heat Source Shift

The default heating source is heat pump. 
If ambient is range out of heat pump, heat pump will stop 
running, the unit will shift automatically to activate E-heater and 
show the icon LA(

   

) on the display, then  if the ambient 

temperature goes into the running range of heat pump again, it 
will stop E-heater and shift automatically to heat pump again, 
and the icon LA(

) will be extinguished.

If the target setting water temperature is higher than Max. 
temp(Heat pump), the unit will activate heat pump firstly to the 
Max. temperature, then stop heat pump, activate E-heater to 
continually heat water to the target temperature.

If manually activate the E-heater running when heat pump 
running, E-heater and heat pump will work together until the 
water temperature gets to target temperature. So if want to heat 
quickly, please manually activate E-heater.

T4

˘

-7

70

70

70

70

70

--

60

70

45

--

-7≤T4

˘

-2 -2≤T4

˘

2 2≤T4

˘

43

43≤T4

NOTE

If only use E-heater, about only 75 liters water will be heated, so 
must set higher target water temperature if ambient temperature 
is out of heat pump running range.

NOTE

3)

4)

Ambient 
Temp.(T4)

Max.Temp.
(Heat pump)

Max. Temp.
(E-heater)

Table

4-1

Fig.4-4

Fig.4-5

Fig.4-6

If system occurs some malfunctions, error code "E7" and      will 
be shown on the display, then heat pump will stop running, and 
the unit will activate automatically E-heater as the backup heat 
source, but the code "E7" and       will be shown until power off.

About TCO and ATCO
The power of compressor and E-heater will be automatically 
shut-off or turn on by TCO and ATCO.

If the temperature is higher than 78

ć

, the ATCO will automati-

cally shut off the power of compressor and E-heater, and turn on 
it if the temperature fall down below 68

ć

If the water temperature is higher than 85

ć

, the TCO will 

automatically shut off the power of compressor and E-heater. 
After that it needs to be reset manually.

0:00:00

2:24:00

4:48:00

7:12:00

9:36:00

12:00:00

14:24:00

-7 -5

2

7

15 20 25 30 32 35 40 45

Ambient temp(

ć

)

Time(h)

15-45
15-55
15-65
15-70

1

2

3

4

5

6

7

-7 -5

2

7

15 20 25 30 32 35 40 45

Ambient temp(

ć

)

C

O

P(W/W)

15-45
15-55
15-65
15-70

ON/OFF

When ambient temp below 2

ćˈ

heat pump and E-heater will 

take different portions of heating capacity, generally the lower of 
ambient temperature, the lower portion of heat pump will be 
taken as well as the higher portion of E-heater will account for.
More detail please refer to Table.4-1.

FAN

Summary of Contents for SWH-15/190T

Page 1: ...OWNER S MANUAL SWH 15 190T SANITARY WATER HEATER H E A T P U M P S...

Page 2: ......

Page 3: ...mples of a qualified person include licensed plumbers authorized electric company personnel and authorized service personnel WARNING This appliance can be used by children aged from 8 years and above...

Page 4: ...ure of this manual When ordering repair parts please always give the following information 1 Model serial and product number 2 Parts name Front Cover Electronic Control Box Compressor Display Cover El...

Page 5: ...ent instructions lables or the data label from either the outside of the unit or inside of unit panels Ask qualified person to perform the installation of this unit in accordance with local national r...

Page 6: ...r more hydrogen gas will be produced in the water piping system Hydrogen gas is extremely flammable To reduce the risk of injury under these conditions it is recommended that open the hot water tap fo...

Page 7: ...nit mm 2 5 Unit outline dimension unit mm 2 4 If installed in inclosed space The water heater must be located in a space 15m and must have unrestricted air flow As an example a room that has an 2 5 ta...

Page 8: ...in high humidity environment a drainage pan is recommanded as shown as following figure Fig 3 2 50mm larger than the dia of unit Max 22mm Heat Pump Water Heater Fig 3 1 Water inlet or outlet pipes The...

Page 9: ...room Air inlet connects to duct air outlet without duct 2 2 5 5 2 2 5 5 Straight line length m Bent pressure drop Pa Bent s qty Straight line pressure drop Pa m Duct Description Duct Round duct Rectan...

Page 10: ...9 To smoothly drain condensate from unit please install the unit at a horizontal floor Otherwise please ensuring the drain vent is at the lowest place Recommending the inclination angle of unit to th...

Page 11: ...i t c e r i d e m a s e h t g n i p e e k t s u m n o i t c n u f l a m m e t s y s e s i w r e h t o g n i r w d e s u a c y a m l e n a p y a l p s i d D C L m e t I t n e t n o C y t i c a p a c n...

Page 12: ...el Selection High Pressure Switch Tp Comp Discharge Temp Sensor Transformer Output Transformer Input Power Supply Solar Input 300L Fan COMP 4 way Valve EHEAT S V Crank Heater Panel Display Power Suppl...

Page 13: ...ered from freezing All piping properly installed and free of leaks Unit completely filled with water Water temperature limit valve or mixer tap recommanded installed per manufacturer s instructions Co...

Page 14: ...lation Sufficient inlet water pressure between 0 15MPa and 0 65MPa 4 2 1 Checking list before commisionning Close Open Drainpipe shut off valve Open Cool water inlet Close the cool water inlet valve o...

Page 15: ...ly heat water to the target temperature If manually activate the E heater running when heat pump running E heater and heat pump will work together until the water temperature gets to target temperatur...

Page 16: ...display screen during disinfection Unit will quit disinfection if water temperature is higher than 65 and extinguish icon Vacation function After pressing button Unit will automatically heat water to...

Page 17: ...s for 1 second Lock If button is locked will be lightened otherwise will be extinguished If button is under lock mode press any button except unlock button will be lightened will be lightened if scree...

Page 18: ...corresponding value will decrease by pushing When setting temperature press more than 1s temperature value will be decreased continuously When Setting clock timer press more than 1s Clock timer value...

Page 19: ...If press it beyond 10sec please resetting all parameters If screen and buttons are locked press it for 3s to unlock them Manually turn on disinfect function Disinfect Clock Setting Confirm the hour se...

Page 20: ...unit shows LA on display A The heat pump available running ambient range is 7 43 if ambient temperature is out of range system will show above mentioned signal to let user notice it Q Why something t...

Page 21: ...s released or sensor has been broken Contact a qualified person to service the unit EE E heater open circuit error IEH Current difference E heater on e heater off 1A Maybe the E heater has been broken...

Page 22: ...t completely finally remount it to the unit Before shutting the system off for a long time please Shut off the power supply Release all the water in water tank and the pipeline and close all the valve...

Page 23: ...outside of storage tank Hydrophilic aluminum fin inner groove copper tube 28W 560 1680mm 3000W Max pressure 1 0MPa Water tank cap Water heating cap 1450W 3800W 17A Drain pipe Dia DN20 DN20 DN20 PT val...

Page 24: ...uman health which could be consequence of incorrect disposal of waste Ask for more details from local preserve valuable natural resources and help in preventing potential negative impacts to environme...

Reviews: