(1). Lock

3.18  WiFi Function Setting

If the WiFi signal is not good, use the WiFi signal enhanced router. 
The specific situation depends on the actual installation.

APP can only set some common functions of WiFi wired controller: ON/OFF, mode, set temperature, 

FAN speed, etc.

If there is a communication failure for WiFi, after resetting WiFi, the temperature display area of wired

"EWPE Smart" APP can be used to control it. The app can be downloaded via Google Play or App Store.

 controller displays “JF” for 5 seconds, which indicates that the current reset is invalid.

3.19  Other Functions

(3). Selection of the Temperature Sensor

Under the Lock state, any other button press won’t get any response.              
(2). Memory
Memory switchover: Under the “OFF” state of the unit, press Mode and 

 at the same time for 

 WiFi can be only be reset or turned off by the buttons on the wired controller rather than the remote 

controller. 

.

Indoor ambient temperature is sensed at the return air inlet(01 in the timer display area).

.

Indoor ambient temperature is the sensed at the wired controller(02 in the timer display area).

.

Select the temperature sensor at the return air inlet under the cooling, dry and fan modes,

       WiFi networking performance is related to the distance between the wired controller and the router 
and the obstacles between them. During the installation process, the distance between the wired controller 
and the router should be as close as possible, and the obstacles should be as little as possible.

Press FUNCTION under on state of the unit till the unit enters the WiFi setting interface, the temperature 

area will display the WiFi status. Press “▲” or “▼”

 button to turn on WiFi(“ON” is displayed) or turn off WiFi 

(“OFF” is displayed), and then press “SWING/ENTER”button to confirm it. 

Note:

factory setting): Under off status, press “FUNCTION” + “FAN” combination buttons on its wired controller 
for 5s. Once “oC” is displayed,this indicates that reset was successful.

Upon startup of the unit without malfunction or under the “OFF” state of the unit, press 

 and 

▼ 

at the same time for 5s till the wired controller enters the Lock function. In this case, LCD 

displays  . After that, repress these two buttons at the same time for 5s to quit this function.

while select the temperature sensor at the  wired controller under the heating and auto 
modes.(03 in the timer display area).

5s to switch memory states between memory on and memory off. When this function is activated, 
Memory will be displayed. If this function is not set, the unit will be under the “OFF” state after power 

failure and then power recovery.

Memory  recovery: If this function  has been set for the wired controller, the wired

controller after power failure will resume its  original running state upon power recovery. Memory 
contents: ON/OFF, Mode, set temperature, set fan speed and Lock function.

When using the APP for the first time, please reset the WiFi function

controller (reset WiFi to ex-

Under OFF state of the unit, press both “FUNCTION” and “TIMER” for five seconds to go the 

commissioning status. Under this status, adjust the display in the temperature display area to “00” 
through the button “MODE”, and then adjust the option of the temperature sensor in the timer display 

area through the button ▲ or ▼.

 of wired 

Summary of Contents for SWC-04

Page 1: ... Ver WIRED CONTROLLER SWC 04 EN User Manual 01 19 07 2021 ...

Page 2: ... R I G I N A L I N S T R U C T I O N S I M P O R TA N T N O T E Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference ...

Page 3: ...esen Link ein Termék kézikönyvének letöltéséhez írja be a modell megnevezését az alábbi linkre Za prenos navodil za uporabo tega izdelka vnesite ime modela na tej po vezavi Per scaricare il manuale di questo pro dotto inserisci il nome del modello a questo link Чтобы загрузить руководство для этогопродукта введитеобозначение модели по следующей ссылке Para descargar el manual de este pro ducto ing...

Page 4: ...ose set temperature is adjustable under auto mode the wired controller will receive the mode signal of remote controller rather than its set temperature under the auto mode The wired controller is the universal component When indoor unit has connected with the wired controller display status of indoor unit is decided by the indoor unit Valid status and invalid status are all belong to normal statu...

Page 5: ...tting 7 3 6 Up Down Swing Setting 6 3 15 Health Setting 3 8 Fresh Air Function Setting 3 9 Sleep Setting 3 10 Turbo Setting 3 11 Energy Saving Function Setting 3 12 E heater Setting 3 13 X fan Setting 3 14 Quiet Function Setting 15 14 13 3 16 Absent Setting 16 12 11 9 8 10 3 18 WiFi Function Setting 18 3 17 I Demand Setting 17 3 19 Other Functions 18 4 1 Connection of the Signal Line of the Wired ...

Page 6: ...ontroller SWC 04 1 Fig 2 LCD of the Wired Controller Fig 1 Outside View of the Wired Controller 1 2 LCD of the Wired Controller Wired Controller SWC 04 1 Symbols on LCD 1 1 Outside View of the Wired Controller ...

Page 7: ...is set 15 Display when up and down swing function is set Slave wired controller 16 Fan speed 17 No card 18 No card in gate control system Left right swing 19 Display when left and right swing function is set Icon of slave wired controller it will display when slave wired controller is set this function is unavailable for this unit X fan The fan speed set currently including auto low medium low med...

Page 8: ...e 04 is displayed on the timer display area By pressing them at the same time under off state of the unit will be displayed on the wired controller for the cooling only unit while displayed on the wired controller for the cooling and heating unit Reset the WiFi function Under off status press FUNCTION FAN combination buttons on its wired controller for 5s Once oC is displayed this indicates that r...

Page 9: ...nge is 16 C 30 C 61 F 86 F In the Auto mode the setting temperature is unadjustable Wi Fi Under the ON state of the unit press MODE to switch the operation modes as the following sequence Auto Cooling Dry Fan Heating Note The state shown in Fig 4 indicates the OFF state of the unit after power on The state shown in Fig 5 indicates the ON state of the unit after power on Wi Fi Note If the wired con...

Page 10: ...mer on setting press Timer and then LCD will display xx x hour with hour blinking In this Under the ON State of the unit press Fan and then fan speed of the indoor unit will change circularly as shown in Fig 7 Timer off setting press Timer if LCD won t display xx x hour and then it means the timer setting is canceled Auto High Low Medium low Medium Medium high SWING ENTER Wired Controller SWC 04 ...

Page 11: ...de is turned off When it is set to be fixed swing press SWING ENTER button the unit will circularly switch the swing mode according to the order shown below There are two ways for up and down swing mode simple swing and fixed swing Under off status press SWING ENTER button and button simultaneously for 5 seconds then switch for simple swing and fixed swing is done Timer range 0 5 24hr Every press ...

Page 12: ...s function Press SWING ENTER button to cancel swing Swing On Press FUNCTION under on state of the unit to activate the swing function In this case will blink After that press SWING ENTER to make a confirmation Swing Off When the Swing function is on press FUNCTION to enter the Swing setting interface Sleep Turbo or X fan setting is the same as the Swing setting After the setting has been done it h...

Page 13: ...resh air valve setting mode Previous temperature display position will display the level of fresh air valve Press or button to adjust the level of fresh air valve within the range from 1 to 10 Then press SWING ENTER button to activate this function valve function option When icon flashes if you press SWING ENTER button without pressing or button fresh air valve function will be canceled if you pre...

Page 14: ...ENTER button to cancel sleep Press SWING ENTER button to turn on sleep Sleep off When the Sleep function is activated press FUNCTION to enter the Sleep setting interface After that press SWING ENTER to can this function Sleep on Press FUNCTION under on state of the unit till the unit enters the Sleep setting interface Press SWING ENTER to confirm the setting Wired Controller SWC 04 ...

Page 15: ...e quick cooling or heating so that the room temperature can quickly approach the setting value In the Cooling or Heating mode press FUNCTION till the unit enters the Turbo setting interface Press SWING ENTER to turn on turbo function When the Turbo function is activated press FUNCTION to enter the Turbo setting interface and then press SWING ENTER to cancel this function Press SWING ENTER to turn ...

Page 16: ...energy saving function will be canceled if you press SWING ENTER button after pressing or button energy saving function will be activated When the unit runs under the HEAT mode press FUNCTION button to select SAVE function option with SAVE flashing and then press or to adjust the upper limit after that press SWING ENTER button to activate this function Note under energy saving setting mode press M...

Page 17: ...eating mode E heater is allowed to be Once the wired controller or the remote controller enters the Heating mode this function turned on automatically Wi Fi Press FUNCTION in the Heating mode to enter the E heater setting interface and then press SWING ENTER to cancel this function Wi Fi Wi Fi Press FUNCTION button into this function Press FUNCTION button into auxiliary electric heating function W...

Page 18: ...tically evaporated to avoid mildew In the Cooling or Dry mode press FUNCTION till the unit enters the X fan setting interface and then press SWING ENTER to active this function When the X fan function is activated press FUNCTION to the X fan setting interface and then press SWING ENTER to cancel this function When the X fan function is activated if turning off the unit by pressing ON OFF or by the...

Page 19: ...ion If quiet function has been set press FUNCTION button on the panel to select Quiet function option Wi Fi When Quiet or Auto quiet flashes if you press SWING ENTER button without pressing or button quiet function will be canceled if you press SWING ENTER button after pressing or button quiet function will be activated Wi Fi Press FUNCTION button to select the Quiet function option Turn on the un...

Page 20: ...unction is activated press FUNCTION to enter the Health setting interface After that press SWING ENTER to cancel this function Wi Fi Wi Fi Wi Fi Wi Fi Wi Fi Press FUNCTION button into health state Turn on the unit without turning on health function Press FUNCTION button into health state Press SWING ENTER button to turn off health function Press SWING ENTER button to turn on health function Wired ...

Page 21: ...NG ENTER to confirm the setting 2 setting and fan speed setting are shielded 3 4 This function will be cancelled when switching modes When this function has been set set temperature is displayed in 8 C 46 F In this case temperature Fig 18 Absent Setting This function and sleep function cannot be on simultaneously If Absent function is set firstly and then sleep quiet function is set Absent functio...

Page 22: ...d function 1 This function is only available in cooling mode 2 and fan speed setting are shielded When this function has been set set temperature is displayed in SE In this case temperature setting 3 This function will be cancelled when switching modes 4 This function and sleep function cannot be on simultaneously If I demand function is set firstly and then sleep quiet function is set I demand fu...

Page 23: ...nder on state of the unit till the unit enters the WiFi setting interface the temperature area will display the WiFi status Press or button to turn on WiFi ON is displayed or turn off WiFi OFF is displayed and then press SWING ENTER button to confirm it Note factory setting Under off status press FUNCTION FAN combination buttons on its wired controller for 5s Once oC is displayed this indicates th...

Page 24: ...tric control box of the indoor unit Let the single line of the wired controller through the soleplate of wired controller Connect the signal line of the wired controller to the 4 pin socket of the indoor unit The communication distance between the main board and the wired controller can Under the commissioning status if there is no any operation in 20 seconds after the last button press it will ba...

Page 25: ...dle stand s basing on the requirement Fig 21 shows the installation steps of the wired controller but there are some issues that need your attention 1 Prior to the installation please firstly cut off the power supply of the wire buried in the installation hole that is no operation is allowed with electricity during the whole installation 2 Pull out the four core twisted pair line from the installa...

Page 26: ...3 Schematic diagram of connection wire Connect terminal with wired terminal of patch cord at first connect the connection wire with the patch cord according to fig 25 and then insert the terminal of connection wire into the needle stand CN1 of wired controller and insert the terminal of patch cord into the terminal of wired controller of air conditioner as well controller CN1 connect terminal with...

Page 27: ...tem connection SWC 04 can connect the smart zone controller integrated control system n indicates the number of communication node address programmable wired controller SWC 04 The complete system is composed of the smart zone controller wired controller SWC 04 and communication cable The wired controller SWC 04 can support 16 communication node addresses at the most n 16 Terminal A and terminal B ...

Page 28: ...to electromagnetic interference 4 3 Dismantlement of the Wired Controller then the signal and communication lines of the wired controller must be the shielding twisted pair lines If there is an error occurring during the operation of the system the error code will be displayed on the LCD as show in Fig 28 If multi errors occur at the same time their codes will be displayed circularly Note In event...

Page 29: ...rotection H5 Over power protection L9 IPM Temperature Protection Discharge temperature sensor open short circuited Ld F0 F8 Capacitor charging error PU Compressor phase current sensing circuit error Frequency restricted reduced with whole unit current protection Compressor phase loss reversal protection En High pressure protection E1 System charge shortage or blockage protection F9 Low pressure pr...

Page 30: ...Error Error Code Communication error between IDU and grid connection Communication error between ODU and grid connection Ln LM y2 y3 Main error at grid connection side yb IDU network address error Ip address allocation overflow Wired Controller SWC 04 ...

Page 31: ...n W1F 7LD Great Britain www sinclair world com This product was manufactured in China Made in China R E P R E S E N TAT I V E SINCLAIR Global Group s r o Purkynova 45 612 00 Brno Czech Republic T E C H N I C A L S U P P O R T SINCLAIR Global Group s r o Purkynova 45 612 00 Brno Czech Republic Tel 420 800 100 285 Fax 420 541 590 124 www sinclair solutions com info sinclair solutions com I N F O R M...

Page 32: ...N O T E S ...

Page 33: ...N O T E S ...

Page 34: ...N O T E S ...

Page 35: ...esen Link ein Termék kézikönyvének letöltéséhez írja be a modell megnevezését az alábbi linkre Za prenos navodil za uporabo tega izdelka vnesite ime modela na tej po vezavi Per scaricare il manuale di questo pro dotto inserisci il nome del modello a questo link Чтобы загрузить руководство для этогопродукта введитеобозначение модели по следующей ссылке Para descargar el manual de este pro ducto ing...

Page 36: ...66139901148 ...

Reviews: