background image

Keep the indoor unit and remote controller at least 1 m away
from televisions, radios, stereos, and other similar equipment.
Failing to do so may cause static or distorted pictures.

A dirty air filter will reduce cooling or heating efficiency, please
clean it once two weeks.

5.    ADJUSTING AIR FLOW DIRECTION

6.    MAINTENANCE

While the unit is in operation, you can adjust the air flow louver

to change the flow direction and naturalize the room

temperature evenly. Thus you can enjoy it more comfortably.

Set the air flow direction.

Press the  SWING  button to adjust the louver to the desired
position and press this button again to maintain the louver at
this position.

Adjust the air flow direction automatically.

Press the SWING button, the louver will swing automatically.
While this function is set, the swing fan of indoor unit runs;
otherwise, the swing fan doesn't run. The swing scale of every
side is 30. When the air conditioner isn't in operation (including
when TIMER ON is set),  the SWING button will be invalid.

CAUTION

Before you clean the air conditioner, be sure the power
supply is off.

Maintenance after a long stop period

(eg. at the beginning of the season)

Maintenance before a long stop period

(eg. at the end of the season)

Check and remove everything that might be blocking inlet
and outlet vents of indoor units .

Clean air filters and casings of indoor units.
Refer to "Cleaning the air filter" for details on how  to proceed
and make sure to install cleaned air filters back in the same
position.

Turn on the power at least 12 hours before operating the unit
in order to ensure smoother operation. As soon as the power
is turned on, the remote controller  displays appear.

Let the indoor units run in fan only operation for about half a
day in order to dry the interior of the units.

Clean air filters and casings of indoor units. Refer to "
Cleaning the air filter" for details on how to proceed and
make sure to install cleaned air filters back in the same
position.

Cleaning the air filter

The air filter can prevent the dust or other particulate from
going inside .In case of blockage of the filter , the working
efficiency of the air conditioner may greatly decrease .
Therefore , the filter must be cleaned once two weeks during
long time usage.

If the air conditioner is installed in a dust place , clean the the
air filter frequent.

If the accumulated dust is too heavy to be cleaned  , please
replace the filter with a new one(replaceable air filter is an
optional fitting).

Open the air-in grill

    Push the grill switches towards the middle simultaneously as
    indicated in

figure 3

. Then pull down the air-in grill.

The control box cables ,which are originally connected with
the main body electrical terminators must be pulled off before
doing as indicated above.

1

2

3

4

Take out the air-in grill (together with the air filter shown in
figure 4).

    Pull the air-in grill down at 45  and lift it up to take out the
    grill.

Dismantle the air filter.

Clean the air filter

    Vacuum cleaner or pure water may be used to clean the air
    filter.If the dust accumulation is too heavy , please use soft
    brush and mild  detergent to clean it and dry out in cool place
.

The air-in side should face up when using vacuum cleaner.

(

See Fig. 5

)

The air-in side should face down when using water.

(

See Fig. 6

)

Caution : Do not dry out the air filter under direct
sunshine or with fire.

3

ADJUST IT UP AND DOWN

(figure 2)

Check if the wiring is not broken off or disconnected.

Disconnect the power supply before cleaning and
maintenance. Use dry cloth to clean the unit.

A wet cloth may be used to clean the indoor unit if it is very
dirty.

Never use a damp cloth on the remote controller.

Do not use a chemically-treted duster for wiping or leave such
material on the unit for long.
it may damage or fade the surface of the unit.

Do not use benzine, thinner, polishing powder, or similar
solvents for cleaning.
These may cause the plastic surface to crack or deform.

Summary of Contents for SF-C2M Series

Page 1: ...SF xxxC4M SF xxxC2M USER MANUAL FOUR PIPE CASSETTE TWO PIPE CASSETTE FAN COIL UNIT AIR CONDITIONING...

Page 2: ...Original instructions IMPORTANT NOTE Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future reference...

Page 3: ...plants animals or works of art Before cleaning be sure to stop the operation turn the breaker off or pull out the supply cord Otherwise an electric shock and injury may result In order to avoid elect...

Page 4: ...Max 1 6MPa Min 0 15MPa 4 HINTS FOR ECONOMICAL OPERATION The following should be noticed to ensure an economical operation Adjust the air flow louver properly and avoid direct air flow to room inhabit...

Page 5: ...filter for details on how to proceed and make sure to install cleaned air filters back in the same position Cleaning the air filter The air filter can prevent the dust or other particulate from going...

Page 6: ...et temperature the indoor unit changes to fan mode when the temperature rises up the rotate speed of the fan will rise too It is same in the heating mode Symptom 4 1 Indoor unit When humidity is high...

Page 7: ...s not properly operate except the above mentioned cases or the above mentioned malfunctions is evident investigate the system according to the following procedures see in table 1 8 1 Troubles and caus...

Page 8: ...nfrared signal receiver of the indoor unit and then repeatly push the ON OFF button twice The indication on the display disappears after a lapse of time Check whether the timer operation has come to a...

Page 9: ......

Page 10: ...l recycling or any other form of recycling old appliances you are making an important contribution to the protection of our environment Please ask your local council where your nearest disposal statio...