Sinclair SDV4 F Owner'S Manual Download Page 10

8

owner’s manual

6.    FOLLOWING SYMPTOMS ARE NOT AIR

       CONDITIONER TROUBLES

Symptom 1: The system does not operate

Symptom 2: Change into the fan mode during

                      cooling mode       

                      

The air conditioner does not start immediately after the ON/OFF 
button on the romote controller is pressed. 
If the operation lamp lights, the system is in normal condition.To 
prevent overloading of the compressor motor, the air 
conditioner starts 3 minutes  after  it  is turned ON.

If the operation lamp and the "

PRE-DEF indicator(cooling and 

heating type) or fan only indicator(cooling only type)"

 light, it 

means you choose the heating model, When just starting, if the 
compressor has not started, the indoor unit  appears "anti cold 
wind" protection because of its overlow outlet temperature.

In order to prevent the indoor evaporator frosting, the system 
will change into fan mode automatically, restore to the cooling 
mode after soon.

.

When the room temperature drops to the set temperature, the 
compressor goes off and the indoor unit changes to fan mode; 
when the temperature rises up, the compressor starts again. It 
is same in the heating mode.

Symptom 3: White mist comes out of a unit

Symptom 4: Noise of air conditionerscooling 

Symptom 3.1: Indoor unit

 Symptom 3.2:  Indoor unit, outdoor unit

Symptom 4.1: Indoor unit

When humidity is high during cooling operation If the interior of 
an indoor unit is extremely contaminated, the temperature 
distribution inside a room becomes uneven. It is necessary to 
clean the interior of the indoor unit. Ask your dealer for details 
on cleaning the unit. This operation requires a qualified service 
erson

When the system is changed over to heating operation after 
defrost operation Moisture generated by defrost becomes 
steam and is exhausted.  

Symptom 4.2:  Indoor unit, outdoor unit 

A continuous low hissing sound is heard when the system is in 
operation. 
This is the sound of refrigerant gas flowing through both indoor 
and outdoor units. 

A hissing sound which is heard at the start or immediately after 
stopping operation or defrost operation. 
This is the noise of refrigerant caused by flow stop or flow 
change. 

A continuous low "shah" sound is heard when the system is in 
cooling operation or at a stop. 
When the drain pump (optional accessories) is in operation,this 
noise is heard.

A "pishi-pishi" squeaking sound is heard when the system stops 
after heating operation. 
Expansion and contraction of plastic parts caused by 
temperature change make this noise. 

Symptom 4.3: Outdoor unit 

When the tone of operating noise changes. 
This noise is caused by the change of frequency.

Symptom 5: Dust comes out of the unit 

Symptom 6: The units can give off odours

When the unit is used for the  first time in a long time. 
This is because dust has gotten into the unit.

The unit can absorb the smell of rooms, furniture, cigarettes, 
etc., and then emit it again. 

Symptom 7: The outdoor unit fan does not       
                      spin.

During operation. The speed of the fan is controlled in order to 
optimize product operation. 

Summary of Contents for SDV4 F

Page 1: ...FULL DC INVERTER SYSTEMS OWNER S MANUAL INDOOR UNITS WITH DC FAN MOTOR C O M M E R C I A L A I R C O N D I T I O N E R S S D V 4 Библиотека СОК ...

Page 2: ...owner s manual Original instructions ...

Page 3: ... for information regarding the connection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundeater and get into the food chain damaging your health and well being To prevent refrigerant leak contact your dealer When the system is installed and runs in a small room it is required to keep the concentration of the refrigerant ...

Page 4: ...o mount on the outdoor unit or avoid placing any object on it Falling or tumbling may result in injury Do not operate the air conditioner when using a room fumigation type insecticide Failure to observe could cause the chemicals to become deposited in the unit which could endanger the health of those who are hypersensitive to chemicals Do not place appliances which produce open fire in places expo...

Page 5: ...duct type Use the system in the following temperature for safe and effective operation The Max operation temperature for the air conditioner Cooling Heating 3 AIR CONDITIONER OPERATIONS AND PERFORMANCE Cooling operation Heating operating cooling only type without Mode Temperature Indoor temperature If air conditioner is used outside the above conditions it may cause the unit to function abnormally...

Page 6: ...ir flow down will cause condensing dew on the air outlet and louver surface 1 2 Cooling operation Adjust the louver horizontally Four way cassette type Fig 4 1 Fig 4 2 To maintain the comfortable temperature Adjust the air out direction with using the air out louver Please note the following correct operation for saving energy and achieve the quick and comfortable cooling heating effects The block...

Page 7: ...t and right automatically Manual swing Adjust the louver to achieve the better cooling heating effects when cooling heating When cooling Adjust the louver horizontally When heating Adjust the louver downwards vertically Fig 4 12 Fig 4 13 Fig 4 14 Fig 4 15 Fig 4 16 Console type Auto swing Press SWING button the louver will swing up and down automatically Manual swing Press Air Direction button the ...

Page 8: ...oerature is low So that air does not come into direct contact with people Air is blown upper air outlet When setting the air outlet selection switch to For switching the Auto Manual mode of the lower air outlet one should plug off and restart the unit for mode renewing CAUTION 5 MAINTENANCE Before you clean the air conditioner be sure the power supply is off Check if the wiring is not broken off o...

Page 9: ...wer switch is connected some energy will be consumed even if the unit is not in operation So please disconnect the power to save the energy A degree of filth will be accumulated due to certain performance after several seasons of operation So special maintenance is advised Take out of the batteries from the remove controller NOTE Maintenance after a long stop period eg at the beginning of the seas...

Page 10: ...e temperature distribution inside a room becomes uneven It is necessary to clean the interior of the indoor unit Ask your dealer for details on cleaning the unit This operation requires a qualified service erson When the system is changed over to heating operation after defrost operation Moisture generated by defrost becomes steam and is exhausted Symptom 4 2 Indoor unit outdoor unit A continuous ...

Page 11: ...nits is blocked Doors and windows are open Sunlight directly shine Too much heat resource Outdoor temp is too high Leakage of refrigerant or lack of refrigerant Wait for the comeback of power Switch on the power Replace the fuse Replace the batteries or check the controller Set the temperature properly Wait Check leakage and rightly recharge refrigerant Vacuum and recharge refrigerant Maintenance ...

Page 12: ...signal receiver of the indoor unit when the ON OFF button is pressed Directly transmit the signal transmitter of the remote controller to the infrared signal receiver of the indoor unit and then repeatly push the ON OFF button twice The indication on the display disappears after a lapse of time Check whether the timer operation has come to an end when the TIMER OFF is indicated on the display The ...

Page 13: ... disappear Table 7 4 NO Type Contents Display content Remarks Room temp sensor is abnormal Indoor outdoor unit communication is abnormal Water level switch is abnormal Mode conflict E2 E1 EE E0 After the malfunctions disappear it restores automatically After the malfunctions disappear it restores automatically After the malfunctions disappear it restores automatically When the indoor unit turns to...

Page 14: ...MATION CONCERNING USED REFRIGERANT MEDIUM This unit is containing fluorinated gases included in the Kyoto protocol The maintanance and the liquidation must be carried out by qualified personel Type of refrigerant R410A The composition of the cooling medium R410A 50 HFC 32 50 HFC 125 The quantity of the refrigerant please see the unit label The value GWP 2088 GWP Global Warming Potential In case of...

Reviews: