3. OPERATION RANGE
;YKZNKY_YZKSOTZNKLURRU]OTMZKSVKXGZ[XKLUXYGLK
GTJ
KLLKIZO\KUVKXGZOUT:NK3G^UVKXGZOUTZKSVKXGZ[XKLUX
ZNKGOXIUTJOZOUTKX)UUROTM.KGZOTM
Cooling operation
Heating operating
Mode
Temperature
Outdoor
temperature
Room
temperature
-15
ć̚
43
ć
-15 27
ć̚ć
17 32
ć̚ć
NOTE
1
2
3
If air conditioner is used outside the above conditions, it may
cause the unit to function abnormally.
The phenomenon is normal that the surface of air
conditioning may condense water when the relative larger
humidity in room, please close the door and window.
Optimum performance will be achieved within these
operating temperature range.
≤27
ć
Table 3-1
3
4.2 About power cut
If power is cut during operation, stop all the operation immediately.
Power comes again. The lamp on the display panel of indoor unit
flashes. And then unit will auto-restart.
Mishandling in operation:
If mishandling happens because of lighting or mobile wireless,
please shut off the manual power switch, and turn on again, then
push the ON/OFF button.
4.3 Heating capacity
The heating operation is a heat-pump process that heat will be
absorbed from outdoor air and released in doors. Once the
outdoor temperature is decreased, heating capacity decreased
corredpindingly.
Other heating equipment is suggested to be used together when
outdoor temperature is too low.
In some extreme cold upland that buy another inddoor unit
equipped electrical heater will obtain better performance.(Refer
to indoor unit owner’s manual for details)
NOTE
The motor in Indoor Unit will continue running for 20~30 seconds
for to remove residual heat when the Indoor Unit recoeiving OFF
command during heating operation.
If the air conditioner malfunction occurs because of disturb,
pleasereconnect the air conditioner to power, then turn on it
again.
1.
2.
owner's manual
A protection feature prevents the air conditioner from being
activated for approximately 3 minuites when it restarts
immediately after operation.
4.4 Three-minute protection feature
NOTE
Ƶ
Indicatior Lights.
still lights while the Air Conditioner is not running. But the Check
Indicator
When the Protection Equipment is activated, the Operation
when the Air Conditio ner is to be directed running compulsively.
This Protection Equipment will enable the Air Conditioner to stop
solved.
manual power switch, and restart operation after problem is
When the protection equipment starts, please shut down the
Heating Operation
Cooling Operation
Ƶ
The air outlet of indoor unit is choked
unit
Too much dust and rubbish adhere to the dust filter in the indoor
outdoor unit.
Strong wind is Continuously blowing to the air outlet of the
The air inlet or air outlet of outdoor unit is blocked.
The protection equipment may be activated in following conditions:
4.1 Protection Equipment
4. OPERATION AND PERFORMANCE