Sinclair SDV4-180EA Owner'S Manual Download Page 5

Do not touch the heat exchanger fins. 

These fins are sharp and could result in cutting injuries.

Do not place items which might be damaged by moisture 
under the indoor unit. 

Condensation may form if the humidity is above 80%, the 
drain outlet is blocked or the filter is polluted. 

After a long use, check the unit stand and fitting for 
damage.

 

If damaged, the unit may fall and result in injury.

To avoid oxygen deficiency, ventilate the room 
sufficiently if equipment with burner is used together 
with the air conditioner.

Arrange the drain hose to ensure smooth drainage.

Incomplete drainage may cause wetting of the building, 
furniture etc.

Never touch the internal parts of the controller.

 

Do not remove the front panel. Some parts inside are 
dangerous to touch, and a machine trouble may happen.

Never expose little children, plants or animals directly to 
the air flow. 

Adverse influence to little children, animals and plants may 
result.

Do not allow a child to mount on the outdoor unit or 
avoid placing any object on it.

 

Falling or tumbling may result in injury.

Do not operate the air conditioner when using a room 
fumigation - type insecticide. 

Failure to observe could cause the chemicals to become 
deposited in the unit, which could endanger the health of 
those who are hypersensitive to chemicals.

Do not place appliances which produce open fire in 
places exposed to the air flow from the unit or under the 
indoor unit.

 

It may cause incomplete combuston or deformation of the unit 
due to the heat.

Do not install the air conditioner at any place where 
flammable gas may leak out. 

If the gas leaks out and stays around the air conditioner, a fire 
may break out. 

The appliance is not intended for use by young children 
or infirm persons without supervision.
 
Young children should be supervised to ensure that they 
do not play with the appliance

.

When capacity of indoor unit greater than the sum of 
100%, capacity of indoor unit will be attenuated.

When capacity of indoor unit greater than or equal to the 
sum of 120%, in order to ensure the effectiveness of 
machine, and then try to open the indoor units at 
different time.

The outdoor unit window-shades should be periodic 
cleaning in case of being jammed.

This window-shapes is heat dissipation outlet of components, if being 
jammed will cause the components shorten their service life spans because 
of overheated for a long time.

The temperature of refrigerant circuit will be high, please 
keep the interconnection cable away from the copper 
tube.

2.    PARTS  NAMES

The air conditioner consists of the indoor unit, the 
outdoor unit, the connecting pipe and the remote 
controller.

(see Fig.1)

2

owner's manual

Force Cooling Control 

Force Cooling Control

Fig.2-1

MAIN BOARD

Force cooling 
control button sw1

Display control button sw2

(OUTDOOR UNIT)

sw1

sw2

 

 

 

   

 

 

 

 

 

   

 

 

 

 

   

 

 

 

 

   

 

 

 

   

 

 

 

   

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

  

 

Force

 

cooling

 

control

 

of

 

outdoor

 

unit

 

be

 

pressed

 

once

 

that

 

a

 

order

 

 

to

 

force

 

cooling

 

in

 

indoor

 

unit.

 

When

 

the

 

frequence

 

of

 

outdoor

 

unit

 

 

change

 

to

 

44Hz

 

and

 

then

 

running

 

it;

 

indoor

 

fan

 

run

 

in

 

high

 

speed.

 

 

Press

 

the

 

button

 

again

 

will

 

exit

 

the

 

Force

 

Cooling

 

Control.

 

Display function

 

 

  

Th e   f u n c t i o n   o f   t e x t   r u n   c i r c u l a t es   a s   f ollows.

The surface temperature of 
the cooling fin

PMV opening

Actual current value

Actual voltage AD value

T2 average temperature

Total quantities of the interior 

units

The quantities of the operating 
interior units

The last fault or protection 
code (if there is no fault or 

protection code it will be 
display “nn”)

Display “--”

Normal display

Operating mode 

(0—Stanby; 2—Cooling; 

3—Heating; 4—Forced 
cooling

˅

Operating fan speed grade 

(0—Power off)

The total capacity 
requirements of the 
interior unit

The capacity requirements
 of the revised external unit

T3 piping temperature 

T4 environmert temperature

T5 discharge temperature 

(actual) (if it is over one 
hundred, it will be only 
display the hundreds
 place and the tens place)

Ę

Ę

Ę

Ę

Ę

Ę

Ę

Ę

Ę

Ę

Ę

Ę

Ę

Ę

Model (18 as 
SDV4-180EA)

Ę

Priority mode

˄

Reserved 

˅

Version of the program

Ę

Ę

Ę

protector, which will stop running.

Blocks may decrease the efficiency of the unit or startup the

Pay attention not to block the air inlet and outlet.

of condenser.)

to warm the crankcase heat box to avoid compulsive start 

is supposed to stop running in 24h or shorter time. (This is 

switch. Please do not shut down the power when the unit

12 hours preheating is imperative after turn on the power 

NOTE

Summary of Contents for SDV4-180EA

Page 1: ...FULL DC INVERTER SYSTEMS OWNER S MANUAL SDV4 180EA C O M M E R C I A L A I R C O N D I T I O N E R S S D V 4...

Page 2: ...Original instructions...

Page 3: ...air inlet air outlet Fig 1 All the pictures in this manual are for explanation purpose only They may be slightly different from the air conditioner you purchased depend on model The actual shape shal...

Page 4: ...t in injury or damage to the equipment Failure to observe a warning may result in death The appliance shall be installed in accordance with national wiring regulations Do not use the air conditioner f...

Page 5: ...of machine and then try to open the indoor units at different time The outdoor unit window shades should be periodic cleaning in case of being jammed This window shapes is heat dissipation outlet of...

Page 6: ...erature is too low In some extreme cold upland that buy another inddoor unit equipped electrical heater will obtain better performance Refer to indoor unit owner s manual for details NOTE The motor in...

Page 7: ...ind 4 7 Defrost in the heating operation During heating operation outdoor unit sometimes will frost To increase efficiency the unit will start defrosting automatically about 2 10 minutes and then wate...

Page 8: ...he setting speed Typhoon protection Indoor evaporator hi tempprotection Low pressure protection Hi pressure protection Inverter module protection Compressor discharge protection temperature 2 times of...

Page 9: ...is heard when the system is in cooling operation or at a stop When the drain pump optional accessories is in operation this noise is heard A pishi pishi squeaking sound is heard when the system stops...

Page 10: ...it and indoor unit heat exchanger is dirty The air filter is dirty Inlet outlet of indoor outdoor units is blocked Doors and windows are open Sunlight directly shine Too much heat resource Outdoor tem...

Page 11: ...button is pressed Check whether the signal transmitter of the remote controller is properly directed to the infrared signal receiver of the indoor unit when the ON OFF button is pressed Directly trans...

Page 12: ...tural resources and help in preventing potential negative impacts to environment and human health which could be consequence of incorrect disposal of waste Ask for more details from local authorities...