background image

1

9

Note:

Make sure that the Live wire or Zero line as well as the earth wire in the family power 

socket can not be wrong connected, there should be reliable and no short circuit in the 

diagram.

wrong connection may cause fire.

4.  

1. 

the power cable diameter should be satisfied.

2. Don't drag the power cable emphatically.

3.

1.  

measure.

2. The yellow-green two-color wire in air conditioner is earthing wire and cannot be used

for other propose. It cannot be cut off and be fix it by screw, otherwise it would cause

electric shock.

3. 
4. 

earthing wire with the following place:

Tap water pipe.

Gas pipe.

Contamination pipe.

Other places that professional personnel consider them unreliable.

5.  

An all-pole disconnection switch having a contact separation of at least 3mm in all poles 

should be connected in fixed wiring. For models with a power plug, make sure the plug 

is within reach after installation.

The air switch must have the functions of magnetic tripping and heat tripping, in order
to protect the short circuit and overloading.

6.

5.  

PCB board.

Notices for installation

Safety Requirements For Electric Appliances

Earthing requirements

It should be reliably earthed, and it should be connected to the special earth device,

the installation work should be operated by the professional.

The min. distance from the unit and combustive surface is 1.5m.

The power supply should be used the rated voltage and AC exclusive circuit,

The appliance shall be installed in accordance with national wiring regulations.

Air conditioner is type I electric appliance, thus please do conduct reliable earthing

The earth resistance should accord to the National Criterion.
The user power must offer the reliable earthing terminal. Please don't connect the

The model and rating values for fuses according the silk print on fuse cover or related

Summary of Contents for MS-H07AIC PT

Page 1: ...USER S MANUAL MS H07AIC PT MS H09AIC PT MS H12AIC PT MS H18AIC PT MULTI SYSTEM wall mounted ...

Page 2: ...Thank you for choosing Residential Air Conditioners please read this owner s manual carefully before operation and retain it for future reference Original instructions ...

Page 3: ...MS H07AIC PT MS H09AIC PT MS H12AIC PT MS H18AIC PT ...

Page 4: ...stallation service Notices for installation Installation dimension diagram Install indoor unit Check after installation and test operation Emergency operation 25 Installation and Maintenance of Healthy Filter 26 Configuration of connection pipe and additional volume of refrigerant Never attempt Be sure to follow this instruction The physical product may differ from the drawing in this manual for d...

Page 5: ...e the accumulated dusts that may cause over heating or fire Never splice the power cord or use an extended cord It can cause overheating or fire When having a burning smell or smoke please turn off the power supply and contact with the service center If the abnormity still exists the unit may be damaged and may cause electric shock or fire Please read the following carefully before operating Notic...

Page 6: ... cause a bad influence to them Don t insert your hands or stick into the air intake or outlet vents Don t use the air conditioner for other purposes such as drying clothes preserving foods etc To adjust the airflow direction appropriately When operating the unit to adjust the vertical and lateral air flow direction by use of remote controller Swing louver Guide louver Please don t cut off or damag...

Page 7: ... to indoor in this way to increase room temperature This is the heat pump heating principle its heating capacity will be reduced due to outdoor temperature decrease If outdoor temperature becomes very low please operate with other heating equipments When outdoor temperature is low but high humidity after a long while running frost will form on outdoor unit that will effect the heating effect at th...

Page 8: ...erating temperature range outdoor temperature for cooling only unit is 18 43 for heat pump unit is 7 43 Working temperature range Maximum cooling Maximum heating Indoor sideDB WB o C Outdoor sideDB WB o C 32 23 27 43 26 24 18 ...

Page 9: ...Names and functions of each part Air in Air out Remote controller Front panel Filter Guide louver Wall pipe Bind tape Cool Dry Fan Heat Set temp Run The pattern in displayer 5 ...

Page 10: ...e TIMER ON TIMER OFF CLOCK X FAN page 10 TEMP page 10 TURBO page 10 SLEEP page 11 LIGHT Press it to set fan speed Press it to set auto on timer Press it to set auto off timer Press it set clock 1 6 Press it to set HEALTH function 7 I FEEL Page 9 5 3 2 4 11 10 14 9 12 13 15 16 17 Operation of Remote Controller 3 14 9 10 13 16 12 5 4 15 11 8 17 7 2 1 6 Press it to set AIR function 8 Press it to turn...

Page 11: ...layed when pressing the up down swing button Press this button again to clear the display 21 Up down swing icon After pressing TIMER button ON or OFF will blink This area will show the set time SET TIME display 24 Pressing TEMP button set temperature ambient temperature outdoor ambient temperature and blank is displayed circularly indoor TEMP icon 20 SLEEP icon is displayed by pressing the SLEEP b...

Page 12: ... AUTO fan speed FAN SPEED display 29 is displayed when pressing the AIR button Press this button again to clear the display Optional for some models AIR icon 27 is displayed when pressing the I FEEL button Press this button again to clear the display I FEEL icon 28 is displayed when pressing the HEALTH button Press this button HEALTH icon 30 again to clear the display Operation of Remote Controlle...

Page 13: ...nsed temperature Press this button again to cancel I FEEL function I FEEL 6 MODE 5 Each time you press this button a mode is selected in a sequence that goes from AUTO COOL DRY FAN and HEAT as the following AUTO COOL DRY FAN HEAT Note Only for modelswith heating function After energization AUTO mode is defaulted In AUTO mode the set temperature will not be displayed on the LCD and the unit will au...

Page 14: ... function which enables the unit to reach the preset temperature in the shortest time In COOL mode the unit will blow strong cooling air at super high fan speed In HEAT mode the unit will blow strong heating air at super high fan speed This function is not applicable for some models Press this button to initiate the auto off timer To cancel the auto timer program simply press the button again TIME...

Page 15: ... properly Notes replace the batteries Sketch map for replacing batteries Replacement of Batteries Press and buttons simultaneously to lock or unlock the keypad If the remote controller is locked is displayed In this case pressing any button blinks three times At unit OFF press MODE and buttons simultaneously to switch between and LIGHT 16 17 Press LIGHT button to turn on the display s light and pr...

Page 16: ... temperature setting or fan speed can not be changed The manual switch can be operated as below Turn on the unit Press AUTO STOP button to enter AUTO mode The microcomputer will select the mode COOL HEAT FAN automatically according to the room temperature for reaching comfortable effect Turn off the unit Press the AUTO STOP button to switch off the unit Emergency Operation Manual switch The operat...

Page 17: ... hurt your fingers Take down the air filter At the slot of surface panel to open an angle pull the air fil ter downward and take it out please see the Fig 4 a b To clean the dust adhering to the filters you can either use a vacuum cleaner or wash them with warm water the water with the neutral detergent should below 45 degree and dry it in the shade NOTE Never use water above 45 to clean or it can...

Page 18: ...e batteries of air conditioner are changed or not Clean and care Check before use Check that whether ground wire is properly connected or not Maintain after use Turn main power off Clean the filter and indoor and outdoor units bodies Clear dust and obstructions from the outdoor unit 14 ...

Page 19: ...lem still has so need to clean air conditioner Please contact with the authorized maintenance center Sound of water flow can be heard during the operation The air conditioner is started when it is running the compressor started or stopped running or the unit is stopped sometimes there is swoosh or gurgle the sound is due to refrigerant flowing they are not malfuncti ons In COOL mode sometimes the ...

Page 20: ...nnot operate At this time you need to pull out of the plug and reinsert it Is it in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged If water leakage in the room The air humidity is on the high side Condensing water over flowed The connection position of indoor unit ...

Page 21: ...ug out contact the dealer in following situations There is harsh sound during operation The terrible odors emitted during operation Water is leaking in the room Air switch or protection switch often breaks Carelessy splash water or something into unit There is an abnormal heat in power supply cord Stop running and cut off the power supply Troubleshooting Phenomenon Troubleshooting Indoor unit cann...

Page 22: ...he appliance but not operation for 4 hours for warm up purpose Maintenance Center in the local area Notices for installation Important Notices Basic Requirements For Installation Position Install in the following place may cause malfunction If it is unavoidable contact with service center please Place where strong heat sources vapors flammable gas or volatile object are emitted Place where high fr...

Page 23: ...For models with a power plug make sure the plug is within reach after installation The air switch must have the functions of magnetic tripping and heat tripping in order to protect the short circuit and overloading 6 5 PCB board Notices for installation Safety Requirements For Electric Appliances Earthing requirements It should be reliably earthed and it should be connected to the special earth de...

Page 24: ...ng Space to the wall Space to the wall Air outlet side Space to the floor Above 250 cm Above 15cm Above 15cm Above 15cm Above The dimensions of the space necessary for correct installation of the appliance including the minimum permissible distances to adjacent structures 20 300cm ...

Page 25: ... condensate 2 Fix the mounting plate on the wall with screws 3 Be sure that the mounting plate has been fixed firmly enough to withstand about 60 kg Meanwhile the weight should be evenly shared by each screw 07 09K UNIT Ф Ф 150mm Φ55mm 150mm Wall Wall Mark on the middle of it Gradienter Left Right Rear piping hole Rear piping hole Space to the wall above Space to the wall above 12K UNIT 18K UNIT Φ...

Page 26: ...Do not put the outlet in the water bulge distortion outlet pipe of indoor unit insulating tube connected insulating tube drain hose outlet pipe of indoor unit rubber belt rubber belt Flooded drain hose outlet pipe of indoor unit outlet pipe of indoor unit rubber belt Connect indoor and outdoor electric wires Fig 6 1 Open the surface panel 2 Remove the wiring cover Fig 6 3 Route the power connectio...

Page 27: ...t damage the connection pipe the joint nut couldn t tighten too much otherwise it may cause leakage Spanner Torque wrench Piping Taper nut Indoor unit piping Fig 9 Mounting plate Fixing hook Mounting baord Right Right rear Fig 8 Left rear Left Fig 7 Tailing 1 Tailing 2 Finally wrap it with tape Gas side piping insulation Water drainage pipe Liquid side Piping insulation Gas side pipe External conn...

Page 28: ...voltage in accordance with the rated voltage marked on the nameplate It may cause electric malfunction or damage the part Is the electric wiring and piping connection installed correctly and securely It may cause electric malfunction or damage the part Has the unit been connected to a secure earth connection It may cause electrical leakage Is the power cord specified It may cause electric malfunct...

Page 29: ...tion As for silver ion filter it is invalid when its surface becomes according to the installation instruction Pay special attention to that silver Take out the healthy filter before cleaning and reinstall it after cleaning Installation and Maintenance of Healthy Filter Cleaning and Maintenance Service Life Healthy filter Air filter Healthy filter downwards to remove it See Fig a the front case as...

Page 30: ...additional refrigerant charging amount on the 1 Additional refrigerant charging amount prolonged length of liquid pipe additional refrigerant charging amount per meter 2 When the length of connection pipe is above 5m add refrigerant according to the prolonged length of liquid pipe The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe See Sheet 2...

Page 31: ...ection pipe mm Indoor unit throttle Outdoor unit throttle Liquid pipe Gas pipe Cooling only cooling and heating g m Cooling only g m Cooling and heating g m Ф6 Ф9 5 or Ф12 20 15 20 Ф6 or Ф9 5 Ф16 or Ф19 50 15 50 Ф12 Ф19 or Ф22 2 100 30 120 Ф16 Ф25 4 or Ф31 8 170 60 120 Ф19 250 250 250 Ф22 2 350 350 350 Configuration of connection pipe and additional volume of refrigerant ...

Page 32: ...able natural resources and help in preventing potential negative impacts to environment and human health which could be consequence of incorrect disposal of waste Ask for more details from local authorities nearest collection point in Waste Acts of respective country in the Czech Republic in Act no 185 2001 Coll in the wording of later regulations In case of incorrect disposal of this waste a fine...